未破裂脑动脉瘤血管内栓塞术后长期结果与随访检查
回顾性分析116个随访超过5年的未破裂脑动脉瘤,栓塞后2年内再通19个(16.3%),其中8个(6.8%)接受再治疗;2年内稳定的动脉瘤在平均7年随访中均未再通。动脉瘤最大径较大与再通显著相关(P = .019)。
要点
- 栓塞后2年内未再通的动脉瘤在平均7年随访中保持稳定。
- 再通均发生在栓塞后2年内,2年内再通率16.3%,再治疗率6.8%。
- 动脉瘤最大径较大与再通显著相关(P = .019)。
核心结论
- 栓塞后2年内未观察到再通的动脉瘤在平均7年随访期间保持稳定。
- 该结果可能有助于考虑栓塞后脑动脉瘤随访影像的合适时间跨度和频率。
研究设计与样本
- 回顾性研究,2006年4月至2011年3月间148个未破裂脑动脉瘤接受血管内弹簧圈栓塞,其中116个随访超过5年纳入分析。
- 随访采用时间飞跃法MR血管成像,于术后1天、3-6个月、1年及此后每年进行。
- 平均随访时间为7.0 ± 1.4年。
关键影像表现/征象
- 再通表现为栓塞后2年内出现,共19个(16.3%)动脉瘤。
- 再通动脉瘤中8个(6.8%)接受了再治疗。
- 栓塞后2年内保持稳定的动脉瘤在后续随访中均未检出再通。
诊断标准与关键数值
- 再通率16.3%(19/116),再治疗率6.8%(8/116)。
- 动脉瘤最大径较大与再通显著相关(P = .019)。
临床应用与阅片要点
- 栓塞后2年内的时间飞跃法MR血管成像随访未发现再通,可能提示后续随访频率可参考此时间窗。
- 动脉瘤最大径较大的病例再通风险较高,阅片时需关注。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The appropriate period of follow-up examinations after endovascular embolization for cerebral aneurysms using time-of-flight MR angiography is not well-known. We retrospectively investigated long-term results after endovascular embolization for unruptured cerebral aneurysms and evaluated the periods from embolization to recanalization and retreatment.
MATERIALS AND METHODS: Between April 2006 and March 2011, one hundred forty-eight unruptured aneurysms were treated with endovascular coil embolization. Among them, we investigated 116 unruptured aneurysms, which were followed up for >5 years. Time-of-flight MR angiography was performed at 1 day, 3-6 months, 1 year after the procedure, and every year thereafter.
RESULTS: The mean follow-up period was 7.0 ± 1.4 years. Recanalization was observed in 19 (16.3%) aneurysms within 2 years. Among them, retreatment for recanalization was performed in 8 (6.8%) aneurysms. No recanalization was detected in any aneurysms that had been stable in the first 2 years after embolization. A larger maximum aneurysm size was significantly correlated with recanalization (P = .019).
CONCLUSIONS: Aneurysms in which recanalization was not observed within 2 years after endovascular coil embolization were stable during a mean follow-up of 7 years. This result may be helpful in considering the appropriate span or frequency of follow-up imaging for embolized cerebral aneurysms.
引用
- Murakami T, Nishida T, Asai K, et al. Long-Term Results and Follow-Up Examinations after Endovascular Embolization for Unruptured Cerebral Aneurysms. AJNR Am J Neuroradiol. 2019. PMID: 31248865. doi:10.3174/ajnr.A6101
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。