PubMed 文献 · Radiol Cardiothorac Imaging · 2019-06-06

前瞻性比较自由呼吸心肺同步平衡稳态自由进动电影MRI与屏气参考技术在镇静儿童和青少年中的左、右心室容积、功能及图像质量。队列1(30例能屏气)中两种序列容积指标和图像质量相当;队列2(63例不能屏气)自由呼吸图像质量多数为良好或优秀。结论认为在不能持续屏气的镇静儿童、青少年和年轻成人中,自由呼吸与屏气技术的容积、功能相当且图像质量非劣。

要点

  • 自由呼吸心肺同步电影MRI在不能屏气的镇静儿童中左、右心室容积和功能与屏气技术相当。
  • 自由呼吸序列263个电影序列中图像质量优秀37个、良好197个、合格26个、欠佳3个。
  • 队列1中自由呼吸与屏气采集一叠14层图像的实际采集时间均为6.1分钟。

核心结论

  • 在不能持续屏气的镇静儿童、青少年和年轻成人队列中,自由呼吸与屏气参考技术的左、右心室容积和功能相当,图像质量非劣。

研究设计与样本

  • 前瞻性研究,队列1纳入30例能屏气患者(平均年龄19岁,范围9-69岁),接受参数相同的屏气和自由呼吸电影短轴成像。
  • 队列2纳入63例不能屏气患者,其中50例镇静(平均年龄9岁,范围4个月至28岁)、13例未镇静(平均年龄21岁,范围8-58岁),接受多切面自由呼吸电影成像。
  • 自由呼吸序列为心肺同步平衡稳态自由进动电影MRI,时空分辨率与屏气成像等效。
  • 队列1比较左、右心室容积定量分析,所有患者进行图像质量定性评分。

诊断标准与关键数值

  • 队列2的263个电影序列中,自由呼吸图像质量评分为优秀37个、良好197个、合格26个、欠佳3个。
  • 队列1中屏气与自由呼吸序列的全局左心室和右心室容积指数及图像质量评分相当。
  • 队列1中一叠14层图像的自由呼吸实际采集时间为6.1分钟±1.9(标准差),屏气为6.1分钟±2.6,两者相当。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To prospectively compare left ventricular and right ventricular volume, function, and image quality of a free-breathing (FB) cardiorespiratory synchronized balanced steady-state free precession cine MRI sequence with that of a standard of reference breath-hold (BH) technique in sedated children and adolescents who are unable to perform BHs.

MATERIALS AND METHODS: Cohort 1 included 30 patients able to perform BHs (mean age, 19 years; age range, 9-69 years). Cohort 1 underwent both BH and FB cine short-axis imaging with identical acquisition parameters. Cohort 2 included 63 patients unable to perform BHs (50 sedated patients [mean age, 9 years; age range, 4 months to 28 years], 13 unsedated patients [mean age, 21 years; age range, 8-58 years]). Cohort 2 underwent FB cine imaging in multiple views with spatiotemporal resolution equivalent to BH imaging. Comparative quantitative analysis was performed for left ventricular and right ventricular volumes in cohort 1 and for qualitative image quality scores in all patients.

RESULTS: Global left ventricular and right ventricular volumetric indexes and image quality scores were comparable between BH and FB sequences in cohort 1. FB image quality was graded as excellent (37 sequences), good (197 sequences), adequate (26 sequences), and suboptimal (three sequences) for 263 cine sequences in cohort 2. In cohort 1, de facto image acquisition time for FB (6.1 minutes ± 1.9 [standard deviation]) was comparable to the equivalent for BH (6.1 minutes ± 2.6) for a stack of 14 sections.

CONCLUSION: In cohorts of sedated children, adolescents, and young adults unable to perform BHs consistently, left ventricular and right ventricular volumes and function were comparable and image quality was noninferior between FB and standard of reference BH techniques.© RSNA, 2019.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Pednekar AS, Jadhav S, Noel C, et al. Free-breathing Cardiorespiratory Synchronized Cine MRI for Assessment of Left and Right Ventricular Volume and Function in Sedated Children and Adolescents with Impaired Breath-holding Capacity. Radiol Cardiothorac Imaging. 2019. PMID: 33778501. doi:10.1148/ryct.2019180027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。