文献速递儿科影像技术与安全MR

计算机辅助放射学审计中的自动化数据提取与报告分析:死后儿科影像的实践启示

Automated data extraction and report analysis in computer-aided radiology audit: practice implications from post-mortem paediatric imaging.
PubMed 文献 · Clin Radiol · 2019-05-31

回顾性分析大奥蒙德街儿童医院5.5年内460例全身死后MRI检查,用自制程序批量处理DICOM文件并用自然语言处理提取报告中的诊断图像质量信息,数据提取总诊断准确率96.7%(445/460,95%CI:94.7-98%),完全方案依从305/460(66.3%),简化方案140/460(30.4%),91.9%(423/460)检查具诊断质量。

要点

  • 自制程序可在数小时内从约80 GB数据中提取全部研究参数,数据提取总诊断准确率96.7%(445/460,95%CI:94.7-98%)。
  • 完全方案305/460(66.3%)中97.7%(298/305)具诊断质量,简化方案140/460(30.4%)中79.3%(111/140)具诊断质量。
  • 仅5例对所有身体系统均无诊断价值,均体重<100 g(24.7-72 g)且采用简化方案。

核心结论

  • 本研究以死后儿科影像为例,证明自动化方法可成功用于审计和质量评估的数据收集,自动化工作流程建立后再次审计将很简便。

研究设计与样本

  • 回顾性审查大奥蒙德街儿童医院5.5年内460例全身死后MRI检查对完整或简化成像序列方案的依从性。
  • 开发简易计算机程序批量处理DICOM文件提取成像序列细节,并用自然语言处理对已授权报告进行诊断图像质量的自动化信息提取。

诊断标准与关键数值

  • 程序从全部数据集(约80 GB)提取研究参数仅需数小时,自然语言处理提取诊断图像质量信息的总体数据提取诊断准确率为96.7%(445/460,95%CI:94.7-98%)。
  • 完全成像方案依从305/460(66.3%),简化方案140/460(30.4%)。
  • 总体423/460(91.9%)检查具诊断质量,其中完全方案298/305(97.7%)、简化方案111/140(79.3%)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To determine local departmental adherence to the paediatric post-mortem magnetic resonance imaging (MRI) protocols, using a customised automated computational approach.

MATERIALS AND METHODS: A retrospective review of 460 whole-body post-mortem MRI examinations performed at Great Ormond Street Hospital for Children over a 5.5-year period was assessed for adherence to a full or abbreviated imaging sequence protocol. A simple computer program was developed to batch process DICOM (digital imaging and communications in medicine) files, extracting imaging sequence details, followed by natural language processing (NLP) of authorised reports to automate information extraction of diagnostic image quality.

RESULTS: The program was able to extract study parameters from the entire dataset (approximately 80 GB of data) in a few hours, and retrieve information on diagnostic image quality using NLP with an overall diagnostic accuracy for data extraction of 96.7% (445/460, 95% confidence interval [CI]: 94.7-98%). The full imaging protocol was adhered to in 305/460 (66.3%) cases, and an abbreviated protocol in 140/460 (30.4%) cases. Overall, 423/460 (91.9%) of studies were of diagnostic quality. These included 298/305 (97.7%) of the full protocol, 111/140 (79.3%) of the abbreviated protocol. In only five cases were the examinations non-diagnostic for all body systems, all of whom weighed <100 g (24.7-72 g) and imaged using the abbreviated protocol.

CONCLUSION: The present study demonstrated a successful application of an automated approach for data collection for audit and quality assessment purposes using paediatric post-mortem imaging as a specific example. Re-audit of these data following change implementation will be straightforward now that the automated workflow is clearly established.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Shelmerdine SC, Singh M, Norman W, et al. Automated data extraction and report analysis in computer-aided radiology audit: practice implications from post-mortem paediatric imaging. Clin Radiol. 2019. PMID: 31160039. doi:10.1016/j.crad.2019.04.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。