血栓内微泡增强超声加速导管接触性溶栓治疗深静脉血栓的临床研究
本研究将导管接触性溶栓(CDT)与血栓内微泡增强超声溶栓(IMUT)联合用于急性下肢深静脉血栓(DVT)患者,研究组13例接受CDT+IMUT,历史对照组43例仅接受CDT。结果显示研究组平均溶栓时间(5.23±1.59天)显著短于对照组(10.00±2.69天),尿激酶总剂量([3.82±1.68]×10^6 IU)低于对照组([4.99±2.26]×10^6 IU),两组均未发生操作相关并发症。
要点
- CDT联合IMUT可使急性下肢DVT平均溶栓时间由10.00±2.69天缩短至5.23±1.59天。
- 联合IMUT后尿激酶总剂量由(4.99±2.26)×10^6 IU降至(3.82±1.68)×10^6 IU。
- 两组均未观察到操作相关并发症。
核心结论
- CDT联合IMUT可安全、有效地提高溶栓效果,研究组平均溶栓时间显著短于对照组,尿激酶总剂量低于对照组,两组均无操作相关并发症。
研究设计与样本
- 临床研究,研究组13例急性下肢DVT患者接受CDT联合IMUT,历史对照组43例仅接受CDT;IMUT使用1 MHz空气背衬换能器,脉冲长度100 μs、脉冲重复频率100 Hz、压力1 MPa。
诊断标准与关键数值
- 研究组平均溶栓时间5.23±1.59天,显著短于对照组的10.00±2.69天。
- 研究组尿激酶总剂量(3.82±1.68)×10^6 IU,低于对照组的(4.99±2.26)×10^6 IU。
- 两组均未记录到操作相关并发症。
临床应用与阅片要点
- 使用1 MHz空气背衬换能器、脉冲长度100 μs、脉冲重复频率100 Hz、压力1 MPa进行血栓内微泡增强超声溶栓。
- CDT过程中可将微泡直接递送至血栓内以增强超声溶栓效果。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Insufficiency of microbubbles in the vessel-obstructing thrombus significantly reduces the effectiveness of ultrasound thrombolysis. With catheter-directed thrombolysis (CDT), microbubbles can be delivered directly into the thrombus. In this study, we combined CDT with intra-clot microbubble-enhanced ultrasound thrombolysis (IMUT) to investigate its safety and efficiency in thrombolysis in patients with acute lower limb deep vein thrombosis (DVT). For IMUT, a 1-MHz air-backed transducer directed 100-μs-pulse-length and 100-Hz-pulse-repetition pressure at 1 MPa was used. Thirteen DVT patients in the study group were treated with CDT and IMUT. Forty-three DVT patients in the historical control group were treated with CDT alone. The results indicated that the average thrombolysis time of the study group was significantly shorter (5.23 ± 1.59 d) than that of the control (10.00 ± 2.69 d), and the overall urokinase dosage of the study group ([3.82 ± 1.68] × 106 IU) was lower than that of the control ([4.99 ± 2.26] × 106 IU). No procedure-related complications were noted in either group. Therefore, combining CDT with IMUT can improve thrombolysis safely and efficiently.
引用
- Zhu Q, Dong G, Wang Z, et al. Intra-clot Microbubble-Enhanced Ultrasound Accelerates Catheter-Directed Thrombolysis for Deep Vein Thrombosis: A Clinical Study. Ultrasound Med Biol. 2019. PMID: 31160122. doi:10.1016/j.ultrasmedbio.2019.04.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。