文献速递骨肌技术与安全US

AMANDUS项目——应用超声造影(CEUS)评估微灌注以检测下肢感染性骨不连的先进诊断方法

The AMANDUS Project-Advanced Microperfusion Assessed Non-Union Diagnostics With Contrast-Enhanced Ultrasound (CEUS) for the Detection of Infected Lower Extremity Non-Unions.
PubMed 文献 · Ultrasound Med Biol · 2019-05-31

该研究前瞻性纳入109例下肢骨不连患者(胫骨78例、股骨31例),在翻修手术前用超声造影评估骨灌注,通过时间-强度曲线量化峰值增强。感染性与无菌性骨不连的灌注差异有统计学意义(峰值增强P<0.001),检测感染性胫骨和股骨骨不连的敏感度85.1%、特异度88.7%(峰值增强阈值81.2 au)。作者认为将CEUS整合入诊断流程后可更准确地规划单步或多步翻修手术。

要点

  • 感染性与无菌性下肢骨不连的CEUS峰值增强差异有统计学意义(P<0.001)。
  • 检测感染性胫骨和股骨骨不连的敏感度85.1%、特异度88.7%(峰值增强阈值81.2 au)。
  • CEUS可实时显示胫骨和股骨骨不连灌注,可靠区分无菌性与感染性骨不连。

核心结论

  • CEUS可实时显示胫骨和股骨骨不连的灌注,并能可靠区分无菌性与感染性骨不连。
  • 将CEUS整合入诊断常规流程后,可更准确地规划骨不连翻修手术为单步或多步手术。

研究设计与样本

  • 前瞻性研究,纳入109例下肢骨不连患者(胫骨78例、股骨31例),在翻修手术前评估骨灌注。
  • 采用超声造影(CEUS),通过时间-强度曲线量化灌注,指标为峰值增强(PE,任意单位au)。
  • 以翻修手术前的临床判断为参考,比较无菌性与感染性骨不连的灌注差异。

关键影像表现/征象

  • 感染性与无菌性骨不连之间灌注差异有统计学意义(峰值增强,P<0.001)。
  • CEUS可实时显示胫骨和股骨骨不连的灌注。

诊断标准与关键数值

  • 检测感染性胫骨和股骨骨不连的敏感度85.1%、特异度88.7%,峰值增强阈值为81.2 au。

临床应用与阅片要点

  • 作者认为,将CEUS整合入诊断常规流程后,可更准确地规划骨不连翻修手术为单步或多步手术。
  • CEUS可作为独立方法用于区分无菌性与感染性骨不连。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The pre-operative determination of infection plays a decisive role in non-union treatment. This study investigated in a large cohort the diagnostic potential of contrast-enhanced ultrasound (CEUS) as stand-alone method for the differentiation between aseptic and infected non-unions. Of 109 patients with lower extremity non-unions (tibia n = 78, femur n = 31) osseous perfusion with CEUS was prospectively assessed before revision surgery. The perfusion was quantified via time-intensity curves and peak enhancement (PE) (arbitrary unit [au]). Significant perfusion differences between aseptic and infected non-unions were evident (PE, p < 0.001). The sensitivity and specificity for the detection of infected tibial and femoral non-unions could be determined with 85.1% and 88.7% (cutoff PE: 81.2 au). CEUS illustrates tibial and femoral non-union perfusion in real time and discriminates reliably between aseptic and infected non-unions. Consequently, when CEUS is integrated into the diagnostic routine algorithm, non-union revision surgery can be planned more accurately as a single or multistep procedure.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Doll J, Gross S, Weber MA, et al. The AMANDUS Project-Advanced Microperfusion Assessed Non-Union Diagnostics With Contrast-Enhanced Ultrasound (CEUS) for the Detection of Infected Lower Extremity Non-Unions. Ultrasound Med Biol. 2019. PMID: 31155406. doi:10.1016/j.ultrasmedbio.2019.05.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。