股骨远端骺板及邻近干骺端扩散张量成像参数与后续青少年生长的相关性
回顾性分析47例平均年龄14.1岁儿童的膝关节扩散张量成像,在股骨骨骺放置感兴趣区并以部分各向异性阈值0.15、最大转角40°行纤维束示踪。短期生长组(n=25)中纤维束体积较大(R2=0.40)和束长较长(R2=0.38)者身高增长更大(P<0.01);长期生长组(n=36)中纤维束体积较大(R2=0.43)和束长较长(R2=0.32)者生长平台期身高增长更大(P<0.01)。结论认为扩散张量成像参数与成像后生长量相关。
要点
- 股骨远端骺板扩散张量成像纤维束体积和束长与后续身高增长相关。
- 短期生长组纤维束体积R2=0.40、束长R2=0.38,均P<0.01。
- 长期生长组纤维束体积R2=0.43、束长R2=0.32,均P<0.01。
核心结论
- 扩散张量成像随访至评估后1年及骨骼成熟时的生长数据证实,扩散张量成像参数与成像后生长量相关。
研究设计与样本
- 回顾性分析2年内47例儿童(平均年龄14.1岁)的膝关节扩散张量成像,在股骨骨骺放置感兴趣区,以部分各向异性阈值0.15、最大转角40°行纤维束示踪;短期生长组n=25,长期生长组n=36。
诊断标准与关键数值
- 短期生长组纤维束体积R2=0.40、束长R2=0.38与身高增长相关(P<0.01);长期生长组纤维束体积R2=0.43、束长R2=0.32与生长平台期身高增长相关(P<0.01);观察者内和观察者间变异性为良好至优秀。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Diffusion-tensor imaging (DTI) depicts the movement of water through columns of cartilage and newly formed bone and provides information about velocity of growth and growth potential.
OBJECTIVE: To determine the correlation between DTI tractography parameters of the distal femoral physis and metaphysis and the height change after DTI in pubertal and post-pubertal children.
MATERIALS AND METHODS: We retrospectively analyzed DTI images of the knee in 47 children with a mean age of 14.1 years in a 2-year period. In sagittal echoplanar DTI studies, regions of interest were placed in the femoral physis. Tractography was performed using a fractional anisotropy threshold of 0.15 and a maximum turning angle of 40°. The sample was divided to assess short-term and long-term growth after DTI. Short-term growth (n=25) was the height change between height at MRI and 1 year later. Long-term growth (n=36) was the height gain between height at MRI and at the growth plateau.
RESULTS: For the short-term group, subjects with larger tract volume (R2=0.40) and longer track lengths (R2=0.38) had larger height gains (P<0.01). For the long-term group, subjects with larger tract volume (R2=0.43) and longer track lengths (R2=0.32) had a larger height gain at the growth plateau (P<0.01). Intra- and inter-observer variability were good-excellent.
CONCLUSION: Follow-up data of growth 1 year after DTI evaluation and at skeletal maturity confirms that DTI parameters are associated with the amount of post-imaging growth.
引用
- Barrera CA, Bedoya MA, Delgado J, et al. Correlation between diffusion tensor imaging parameters of the distal femoral physis and adjacent metaphysis, and subsequent adolescent growth. Pediatr Radiol. 2019. PMID: 31177318. doi:10.1007/s00247-019-04443-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。