冻结肩患者肩袖肌腱剪切波弹性成像显示僵硬度增加
本研究用剪切波弹性成像联合B型超声评估32例冻结肩患者双侧肩关节的肩袖肌腱、肌肉、关节囊、喙肱韧带及肱二头肌长头,按冻结期与冻结完成期分组比较患侧与健侧。冻结期冈上肌腱和冈下肌腱以及冻结完成期喙肱韧带的剪切波弹性成像值患侧显著高于健侧,后关节囊在兩期及喙肱韧带在冻结完成期患侧显著增厚。作者认为肩袖僵硬度变化也可能与冻结肩相关。
要点
- 冻结期冈上肌腱和冈下肌腱剪切波弹性成像值患侧显著高于健侧。
- 冻结完成期喙肱韧带剪切波弹性成像值患侧显著高于健侧。
- 后关节囊在冻结期和冻结完成期患侧均显著厚于健侧。
核心结论
- 冻结期冈上肌腱和冈下肌腱剪切波弹性成像值均升高,冻结完成期喙肱韧带剪切波弹性成像值也升高;不仅关节囊厚度变化,肩袖僵硬度变化也可能与冻结肩相关。
研究设计与样本
- 研究纳入32例冻结肩患者并分为冻结期和冻结完成期,所有患者均有活动范围受限但无肩袖撕裂;采用剪切波弹性成像联合B型超声测量冈上肌腱、冈下肌腱、冈上肌、冈下肌、小圆肌、上斜方肌和下斜方肌、后关节囊、喙肱韧带及肱二头肌长头的僵硬度,并用B型超声测量后关节囊和喙肱韧带厚度,比较各期患侧与健侧。
诊断标准与关键数值
- 冻结期冈上肌腱剪切波弹性成像值患侧280.4±125.3 kPa vs 健侧178.1±73.3 kPa,患侧显著更高(P<.05)。
- 冻结期冈下肌腱剪切波弹性成像值患侧318.4±110.7 kPa vs 健侧240.8±91.5 kPa,患侧显著更高(P<.05)。
- 冻结完成期喙肱韧带剪切波弹性成像值患侧287.2±135.3 kPa vs 健侧214.1±91.1 kPa,患侧显著更高(P<.05)。
- 冻结期后关节囊厚度患侧1.3±0.2 mm vs 健侧0.9±0.3 mm,患侧显著更厚(P<.01)。
- 冻结完成期后关节囊厚度患侧1.2±0.4 mm vs 健侧0.9±0.3 mm、喙肱韧带厚度患侧4.4±1.4 mm vs 健侧3.3±1.1 mm,患侧均显著更厚(P<.01)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the stiffness and morphologic characteristics of the capsule, rotator cuff tendons and muscles, coracohumeral ligament (CHL), and long head of the biceps in patients with frozen shoulder using shear wave elastography (SWE) with B-mode ultrasound.
METHODS: Thirty-two patients with frozen shoulder were divided into freezing and frozen phases. All patients had limitations of their range of motion without rotator cuff tears. Stiffness was measured by SWE in the supraspinatus (SSp) tendon, infraspinatus (ISp) tendon, SSp muscle, ISp muscle, teres minor muscle, upper and lower trapezius muscles, posterior capsule, CHL, and long head of the biceps. The posterior capsule and CHL thicknesses were also investigated with B-mode ultrasound. All values were compared in the affected and unaffected shoulders in each phase.
RESULTS: The SWE values for the SSp and ISp tendons in the freezing phase and the CHL in the frozen phase were significantly greater on the affected side than the unaffected side (mean ± SD, 280.4 ± 125.3 versus 178.1 ± 73.3, 318.4 ± 110.7 versus 240.8 ± 91.5, and 287.2 ± 135.3 versus 214.1 ± 91.1 kPa, respectively; P < .05). The posterior capsule in both the freezing and frozen phases and the CHL in the frozen phase were significantly thicker on the affected side than the unaffected side (1.3 ± 0.2 versus 0.9 ± 0.3, 1.2 ± 0.4 versus 0.9 ± 0.3, and 4.4 ± 1.4 versus 3.3 ± 1.1 mm; P < .01).
CONCLUSIONS: The SWE values of the both SSp and ISp tendons increased in the freezing phase, and that of the CHL also increased in the frozen phase. Not only the change in thickness of the capsule but also the change in stiffness of the rotator cuff may correlate with frozen shoulder.
引用
- Wada T, Itoigawa Y, Yoshida K, et al. Increased Stiffness of Rotator Cuff Tendons in Frozen Shoulder on Shear Wave Elastography. J Ultrasound Med. 2019. PMID: 31218712. doi:10.1002/jum.15078
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。