文献速递甲状腺与浅表头颈US

计算机软件辅助超声医师诊断甲状腺影像报告和数据系统3级和4级甲状腺占位性病变的价值

Value of Computer Software for Assisting Sonographers in the Diagnosis of Thyroid Imaging Reporting and Data System Grade 3 and 4 Thyroid Space-Occupying Lesions.
PubMed 文献 · J Ultrasound Med · 2019-06-25

研究评估甲状腺超声计算机辅助诊断软件(AmCAD-UT)辅助超声医师诊断甲状腺影像报告和数据系统3级和4级占位性病变的能力。回顾性组234例经手术病理证实的甲状腺病变中,软件辅助诊断的敏感度和准确度显著高于医师独立诊断。前瞻性组220例拟行穿刺活检者中,软件建议与穿刺病理结果的一致性κ=0.786,诊断符合率93.6%。结论认为AmCAD-UT检测可提高超声医师诊断能力,其诊断建议与穿刺活检结果较一致,可减少不必要的诊断性穿刺活检。

要点

  • 软件辅助诊断(UD+CAD)的敏感度和准确度显著高于医师独立诊断(P<0.05)。
  • 软件建议与穿刺活检病理结果的一致性κ=0.786,诊断符合率93.6%。
  • 软件诊断建议可减少不必要的诊断性穿刺活检。

核心结论

  • AmCAD-UT检测提高了超声医师诊断甲状腺影像报告和数据系统3级和4级占位性病变的能力;其诊断建议与穿刺活检结果较一致,可减少不必要的诊断性穿刺活检。

研究设计与样本

  • 回顾性组纳入234例经手术病理证实的甲状腺病变,比较同一超声医师独立诊断、参考软件后诊断及软件单独诊断的敏感度、特异度和准确度;前瞻性组纳入220例拟行穿刺活检的甲状腺占位性病变患者,将超声图像导入AmCAD获取穿刺活检或定期随访建议,与穿刺病理结果比较一致性和符合率。

诊断标准与关键数值

  • 回顾性组中,软件单独诊断和软件辅助医师诊断的敏感度和准确度均显著高于医师独立诊断(P<0.05)。
  • 前瞻性组中,软件与穿刺活检结果的整体组内相关系数κ=0.786,诊断符合率93.6%。

临床应用与阅片要点

  • 作者结论认为AmCAD-UT检测可提高超声医师对甲状腺影像报告和数据系统3级和4级占位性病变的诊断能力,其诊断建议可减少不必要的诊断性穿刺活检。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To analyze the ability of thyroid ultrasound computer-aided diagnosis (CAD) detection software (AmCAD-UT; AmCAD BioMed Corporation, Taipei, Taiwan) to assist sonographers in diagnosing Thyroid Imaging Reporting and Data System grade 3 and 4 space-occupying lesions and to provide evidence for ultrasound doctors (UDs) to use the diagnostic recommendations of the AmCAD system to inform clinical decisions.

METHODS: In group 1, a retrospective study was performed on 234 cases of thyroid lesions confirmed by surgical pathology. The sensitivities, specificities, and accuracies of the diagnoses determined by the same UD independent of the software (UD) and after consulting the CAD software (UD + CAD) and by the software alone (CAD) were compared. In group 2, a prospective study was performed on 220 individuals with thyroid space-occupying lesions recommended by physicians from our hospital to undergo needle biopsy to confirm the diagnosis. Ultrasound images were imported into AmCAD, and recommendations for needle biopsy or periodic follow-up were obtained. According to the pathologic results of needle biopsy, consistency and coincidence rates of diagnostic recommendations for AmCAD were obtained.

RESULTS: In group 1, CAD and UD + CAD diagnoses achieved significantly higher sensitivities and accuracies of diagnosis than did independent diagnosis by the UD (P < .05). In group 2, the software showed an overall intraclass correlation (κ = 0.786) and a diagnosis coincidence rate of 93.6% with needle biopsy results.

CONCLUSIONS: AmCAD-UT Detection improved the ability of UDs to diagnose Thyroid Imaging Reporting and Data System grade 3 and 4 space-occupying lesions. Diagnostic recommendations of AmCAD are relatively consistent with needle biopsy results and can reduce the rate of unnecessary diagnostic needle biopsies.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Lu Y, Shi XQ, Zhao X, et al. Value of Computer Software for Assisting Sonographers in the Diagnosis of Thyroid Imaging Reporting and Data System Grade 3 and 4 Thyroid Space-Occupying Lesions. J Ultrasound Med. 2019. PMID: 31237716. doi:10.1002/jum.15065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。