文献速递乳腺US

超声造影在乳腺导管原位癌诊断中的应用:127例分析

Application of Contrast-Enhanced Ultrasound in the Diagnosis of Ductal Carcinoma In Situ: Analysis of 127 Cases.
PubMed 文献 · J Ultrasound Med · 2019-06-17

本研究对127例经病理证实的乳腺导管原位癌(DCIS)病灶与124例纤维腺瘤(FA)对照行常规超声和超声造影(CEUS),分析形态学特征与定量参数。CEUS显示DCIS与FA在灌注特征上存在显著差异, logistic回归筛选出与DCIS相关的独立风险因素,各指标AUC均>0.6(P<.05)。作者认为CEUS有助于区分DCIS与FA。

要点

  • CEUS定量参数中,流入时间、达峰时间、峰值强度及增强强度在DCIS与FA间差异有统计学意义(P<.05)。
  • 形态学特征如增强模式、灌注缺损、周边高增强、增强范围、瘤内血管及穿支血管与DCIS相关(P<.05)。
  • 多因素logistic回归各指标AUC均>0.6,提示CEUS对鉴别DCIS与FA有诊断价值。

核心结论

  • DCIS的超声造影增强模式和定量参数与纤维腺瘤不同,提示CEUS在区分DCIS与FA方面可能非常有用。

研究设计与样本

  • 共纳入127例经组织病理学证实的DCIS病灶和124例纤维腺瘤(FA)作为对照,行常规超声和实时灰阶超声造影(CEUS)检查,分析DCIS与FA的CEUS表现(形态学特征和定量参数),并采用二元logistic回归筛选独立风险因素。

关键影像表现/征象

  • CEUS显示DCIS与FA在流入时间、增强模式、增强强度、血流灌注缺损、周边高增强、增强范围、瘤内血管及其走行和扩张程度、穿支血管方面差异有统计学意义(P<.05)。
  • 多因素logistic回归分析中,流入时间、增强强度、血流灌注缺损、增强范围、穿支血管、到达时间、峰值强度的AUC均>0.6(P<.05)。

诊断标准与关键数值

  • 流入时间、增强强度、血流灌注缺损、增强范围、穿支血管、到达时间、峰值强度的受试者工作特征曲线下面积(AUC)均>0.6(P<.05)。

临床应用与阅片要点

  • 阅片时可关注CEUS的流入时间、增强模式与强度、灌注缺损、周边高增强、增强范围、瘤内血管走行及穿支血管等特征,这些特征与DCIS相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To explore the characteristics of breast ductal carcinoma in situ (DCIS) on real-time grayscale contrast-enhanced ultrasound (CEUS) imaging and the diagnostic value of CEUS in DCIS.

METHODS: A total of 127 histopathologically confirmed DCIS lesions and 124 fibroadenomas (FAs; controls) were subjected to conventional ultrasound and CEUS. Next, the CEUS findings of DCIS and FA lesions, including morphologic features and quantitative parameters, were analyzed.

RESULTS: Binary logistic regression was used to identify the independent risk factors from DCIS and FA lesions detected by CEUS. Contrast-enhanced ultrasound revealed significant differences between DCIS and FA. The wash-in time, enhancement mode, enhancement intensity, blood perfusion defects, peripheral high enhancement, enhancement scope, intratumoral vessels and their courses and dilatation degree, and penetrating vessels on CEUS were identified as features correlated with DCIS (P < .05). Moreover, a multivariate logistic regression analysis was developed, and the area under receiver operating characteristic curve of each index was generated, including the wash-in time, enhancement intensity, blood perfusion defects, enhancement scope, penetrating vessels, arrival time, and peak intensity (P < .05; area under the curve, >0.6).

CONCLUSIONS: The contrast-enhancement patterns and DCIS parameters appeared different from FA lesions, thus suggesting that CEUS can be very useful in distinguishing DCIS from FA lesions.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Li W, Zhou Q, Xia S, et al. Application of Contrast-Enhanced Ultrasound in the Diagnosis of Ductal Carcinoma In Situ: Analysis of 127 Cases. J Ultrasound Med. 2019. PMID: 31206200. doi:10.1002/jum.15069

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。