文献速递乳腺乳腺X线

基于人群筛查 program 中数字乳腺断层摄影与标准数字乳腺X线摄影连续检查的筛查结局

Screening outcome for consecutive examinations with digital breast tomosynthesis versus standard digital mammography in a population-based screening program.
PubMed 文献 · Eur Radiol · 2019-06-11

该回顾性研究纳入 BreastScreen Norway 2008-2016 年间 35,736 名至少接受两次连续筛查的女性,比较数字乳腺断层摄影(DBT)与标准数字乳腺X线摄影(DM)在连续筛查轮次中的早期绩效指标。结果显示 DBT 筛查的召回率更低、筛查检出乳腺癌率更高,且这些差异在连续两轮筛查中可持续;两组间 interval cancer 率无统计学差异。

要点

  • DBT 筛查较 DM 召回率更低,且该降低在连续两轮筛查中可持续。
  • DBT 筛查的筛查检出乳腺癌率高于 DM,阳性预测值亦更高。
  • DBT 与 DM 筛查的 interval cancer 率无统计学差异。

核心结论

  • DBT 筛查的较低召回率与较高筛查检出乳腺癌率在连续两轮筛查中可持续;DBT 的阳性预测值高于 DM;各研究组间 interval cancer 率无统计学差异;DBT 相比 DM 肿瘤特征趋于预后有利,但更晚期癌症率无差异;癌症检出增加及未来死亡率降低的临床意义尚不清楚。

研究设计与样本

  • 回顾性研究,纳入 BreastScreen Norway 2008-2016 年间 35,736 名至少接受两次连续筛查的女性,以连续两次筛查检查对为分析单位,按筛查技术分为 DM after DM、DBT after DM、DM after DBT、DBT after DBT 四组,比较组间早期绩效指标。

诊断标准与关键数值

  • DM after DM 组召回率为 3.6%,且高于其他所有研究组(p < 0.001)。
  • DM after DM 组筛查检出乳腺癌率为 4.6/1000;DBT after DM 组为 9.9/1000,DBT after DBT 组为 8.3/1000(相对 DM after DM 组 p < 0.001);DM after DBT 组为 4.3/1000。
  • DBT after DBT 或 DBT after DM 组的 tubular carcinoma 率高于 DM after DM 组(p < 0.01)。
  • DBT after DM 组组织学分级 1 级肿瘤率高于 DM after DM 组(p < 0.001)。
  • 各研究组间 interval cancer 率无统计学差异。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文指出关于 DBT 筛查超过一轮筛查轮次的早期绩效指标知识有限。
  • 癌症检出增加及未来死亡率降低的临床意义尚不清楚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To retrospectively investigate early performance measures of digital breast tomosynthesis (DBT) versus standard digital mammography (DM) for consecutive screening rounds.

METHODS: We included information about 35,736 women screened in BreastScreen Norway, 2008-2016, with at least two consecutive screening examinations. The pair of two consecutive screening examinations was the unit of analysis, and results from the subsequent examination were the measure of interest. Screening technique changed during the study period, resulting in four study groups: DM after DM, DBT after DM, DM after DBT, and DBT after DBT. We compared selected early performance measures between the study groups.

RESULTS: Recall for DM after DM was 3.6% and lower for all other study groups (p < 0.001). The rate of screen-detected breast cancer was 4.6/1000 for DM after DM; for DBT after DM and DBT after DBT, it was 9.9/1000 and 8.3/1000, respectively (p < 0.001 relative to DM after DM), and for DM after DBT 4.3/1000. The rate of tubular carcinoma was higher for DBT after DBT or after DM compared with DM after DM (p < 0.01). The rate of histologic grade 1 tumors was higher for DBT after DM compared with DM after DM (p < 0.001). We did not observe any statistical difference in the interval cancer rates.

CONCLUSIONS: Lower recall and higher cancer detection rates for screening with DBT were sustainable over two consecutive screening rounds. Positive predictive values were higher for DBT than DM. There were no differences in the interval cancer rates between the study groups.

KEY POINTS: • There is limited knowledge about early performance measures for screening with digital breast tomosynthesis beyond one screening round. • A decline in recall rate and an incline in the rate of screen-detected breast cancer were observed for women screened with DBT compared with DM, irrespective of prior screening technique. The interval breast cancer rate did not differ statistically for women screened with DBT versus DM. • Tumor characteristics tended to be prognostic favorable for DBT compared with DM with no differences in rates of more advanced cancers. The clinical significance of increased cancer detection and the potential for future mortality reduction remain unknown.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Hovda T, Brandal SHB, Sebuødegård S, et al. Screening outcome for consecutive examinations with digital breast tomosynthesis versus standard digital mammography in a population-based screening program. Eur Radiol. 2019. PMID: 31187221. doi:10.1007/s00330-019-06264-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。