新型重建算法减少乳腺断层摄影中的高衰减伪影
研究在18例乳腺切除标本的断层摄影图像上评估一种新型伪影减少重建算法的效果,该算法通过预分割去除投影图像中高衰减物体再重建。结果显示伪影明显减少,病灶遮蔽基本避免,模体信号差与背景比提高97%,乳腺切除标本提高69%。
要点
- 新型重建算法可明显减少金属物体所致平面外伪影,使病灶可见性接近无针标准图像。
- 读者能自信判断针位置的总体比例为76±8%,全乳切除标本为94±6%,部分切除为62±17%。
- 伪影减少后信号差与背景比在模体提高97%、乳腺切除标本提高69%,伪影扩散函数明显变窄。
核心结论
- 使用新型重建算法减少乳腺断层摄影中的金属伪影,可在金属伪影成为限制因素时(如断层摄影引导活检)从定性和定量上改善临床使用。
研究设计与样本
- 研究经区域伦理审查委员会批准,采集18例乳腺癌女性的部分和全乳切除标本在插入针前后的乳腺断层摄影图像。
- 图像分别用标准重建算法和新型算法重建,后者利用预分割从投影图像中去除高衰减致伪影物体后再重建,并分别在有和无分割下重建后组合为伪影减少重建。
- 标准与伪影减少乳腺断层摄影算法通过乳腺切除标本临床图像和物理拟人模体进行视觉和定量比较,6名读者独立并排评估有无伪影减少时病灶可见性。
关键影像表现/征象
- 与无伪影减少的乳腺断层摄影图像相比,新型重建明显减少平面外伪影的幅度。
- 伪影对病灶的遮蔽基本避免,肿瘤可见性与无针的标准乳腺断层摄影图像相当。
- 伪影减少后信号差与背景比在模体提高97%、在乳腺切除标本提高69%。
- 伪影扩散函数明显变窄。
诊断标准与关键数值
- 总体76±8%(标准差)的病例中读者能自信判断针位置,全乳切除病例为94±6%,部分切除为62±17%。
临床应用与阅片要点
- 在金属伪影可能限制乳腺断层摄影评估时(如断层摄影引导活检),新型重建算法可减少伪影并改善病灶可见性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the effect on reducing the out-of-plane artifacts from metal objects in breast tomosynthesis (BT) using a novel artifact-reducing reconstruction algorithm in specimen radiography.
METHODS AND MATERIALS: The study was approved by the Regional Ethical Review Board. BT images of 18 partial- and whole mastectomy specimens from women with breast cancer were acquired before and after a needle was inserted close to the lesion. The images were reconstructed using both a standard reconstruction algorithm, and a novel algorithm; the latter uses pre-segmentation to remove highly attenuating artifact-inducing objects from projection images before reconstruction. Images were separately reconstructed with and without segmentation, and combined into an artifact-reduced reconstruction. Standard and artifact-reduced BT-algorithms were compared visually and quantitatively using clinical images of mastectomy specimens and a physical anthropomorphic phantom. Six readers independently assessed the visibility of the lesion with and without artifact-reduction in a side-by-side comparison. A quantitative analysis was performed, comparing the signal-difference to background ratio (SDBR) and artifact spread function (ASF) between the two reconstruction methods.
RESULTS: The magnitude of out-of-plane artifacts was clearly reduced with the novel reconstruction compared to BT-images without artifact reduction. Lesion masking by artifacts was largely averted; tumour visibility was comparable to standard BT images without a needle. In 76 ± 8% (standard deviation) of cases overall, readers could confidently state needle location. The same figure was 94 ± 6% for whole mastectomy cases, compared to 62 ± 17% for partial mastectomies. With metal artifact reduction, SDBR increased by 97% in the phantom, and by 69% in the mastectomies. The artifact spread function was substantially narrower.
CONCLUSION: Artifact reduction in BT using a novel reconstruction method enables qualitatively and quantitatively improved clinical use of BT when metal artifacts can be a limiting factor such as in tomosynthesis-guided biopsy.
引用
- Dustler M, Wicklein J, Förnvik H, et al. High-attenuation artifact reduction in breast tomosynthesis using a novel reconstruction algorithm. Eur J Radiol. 2019. PMID: 31153567. doi:10.1016/j.ejrad.2019.04.014