联合应变与剪切波弹性成像减少乳腺病变不必要活检的初步结果
研究纳入267例患者278个BI-RADS 4类病灶,比较应变弹性成像、VTI、VTIQ及联合方法。联合弹性成像将阳性预测值从45.7%提高至63.18%,并使约半数BI-RADS 4A病灶降级而未漏诊癌症,但未识别2例导管内乳头状瘤和1例叶状肿瘤。
要点
- 联合VTI+SE+VTIQ时阴性预测值最高达100%,可用于排除恶性。
- 联合弹性成像使BI-RADS 4A病灶降级比例达50.8%–52.5%,未漏诊癌症。
- 但2例导管内乳头状瘤和1例叶状肿瘤未被识别。
核心结论
- 联合不同弹性成像方法有潜力将BI-RADS 4A病灶降级以减少假阳性活检,且不增加漏诊癌症风险。
研究设计与样本
- 单中心研究,共267例患者278个BI-RADS 4类病灶(151个良性、127个恶性),使用Siemens Acuson S2000超声系统行常规B模式超声、应变弹性成像、VTI和VTIQ检查。
诊断标准与关键数值
- VTI单独应用时阴性预测值最高为91.74%;联合弹性方法阴性预测值高于单一方法,VTI+SE+VTIQ联合时阴性预测值最高达100%。
临床应用与阅片要点
- 联合弹性成像(VTI+SE+VTIQ)使阳性预测值从常规超声的45.7%(127/278)提高至63.18%(127/201)。
局限性
- 2例导管内乳头状瘤和1例叶状肿瘤未被识别。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The aim of our study was to compare strain elastography (SE), acoustic radiation force impulse-inducing Virtual Touch Imaging ([VTI] Siemens Medical Solutions, Mountain View, CA, USA), Virtual Touch Imaging Quantification ([VTIQ] Siemens Medical Solutions) and combined methods in the evaluation of ultrasound (US) Breast Imaging-Reporting and Data System (BI-RADS) category 4 lesions to explore an applicable way to reduce unnecessary biopsy by reducing false positives of conventional US without yielding false-negative cases. A total of 267 patients with 278 BI-RADS category 4 lesions (151 benign and 127 malignant) were evaluated with conventional B-mode US, SE, VTI and VTIQ implemented on a Siemens Acuson S2000 US system. Diagnostic performance, including area under the receiver operating characteristic curve, sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were evaluated. Overall, VTI alone exhibited the highest NPV (91.74%), although combined elastic methods exhibited higher NPV than single methods, with the highest NPV at 100% when the VTI, SE and VTIQ methods were combined. Compared with conventional US, PPV increased from 45.7% (127 of 278) to 63.18% (127 of 201) when adding combined elastography (VTI + SE +VTIQ). In addition, 52.5% (63/120) and 50.8% (61/120) of BI-RADS 4 A lesions were downgraded when using combined methods (VTI + SE and VTI + SE + VTIQ, respectively) without missing any cancer. However, 2 intraductal papillomas and 1 phyllodes tumor were not identified. In conclusion, the combination of different elastic methods have the potential to downgrade BI-RADS 4A lesions to reduce false-positive biopsies without increasing the risk of missing cancers.
引用
- Han J, Li F, Peng C, et al. Reducing Unnecessary Biopsy of Breast Lesions: Preliminary Results with Combination of Strain and Shear-Wave Elastography. Ultrasound Med Biol. 2019. PMID: 31221510. doi:10.1016/j.ultrasmedbio.2019.05.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。