文献速递乳腺技术与安全乳腺X线

利用机器学习提高乳腺X线摄影工作流程效率

Improving Workflow Efficiency for Mammography Using Machine Learning.
PubMed 文献 · J Am Coll Radiol · 2019-05-30

研究使用来自英国六家国民健康服务乳腺筛查中心七千余名女性的乳腺X线摄影数据,构建卷积神经网络联合多任务学习提取影像特征并融合多视图,预测诊断及是否需要额外放射学评估。在阴性预测值维持0.99时,该模型在癌症患病率15%和1%的测试集中分别识别出34%(95%CI 25%-43%)和91%(95%CI 88%-94%)的阴性乳腺X线摄影,从而减少放射科医生需阅读的正常检查数量而不降低诊断准确性。

要点

  • 模型在阴性预测值0.99下,可识别34%(95%CI 25%-43%)的阴性乳腺X线摄影(癌症患病率15%测试集)。
  • 模型在阴性预测值0.99下,可识别91%(95%CI 88%-94%)的阴性乳腺X线摄影(癌症患病率1%测试集)。
  • 机器学习可减少放射科医生需阅读的正常乳腺X线摄影数量,且不降低诊断准确性。

核心结论

  • 机器学习可成功减少放射科医生需阅读的正常乳腺X线摄影数量,且不降低诊断准确性。

研究设计与样本

  • 研究论文;使用来自英国六家国民健康服务乳腺筛查中心七千余名女性的乳腺X线摄影研究数据集;采用卷积神经网络联合多任务学习提取影像特征,并用深度神经网络融合多视图预测诊断及是否需要额外放射学评估;在随机选取的2000例患者上进行十折交叉验证,其余数据用于卷积神经网络训练。

诊断标准与关键数值

  • 在阴性预测值维持0.99时,模型在癌症患病率15%的测试集中识别出34%(95%CI 25%-43%)的阴性乳腺X线摄影,在癌症患病率1%的测试集中识别出91%(95%CI 88%-94%)的阴性乳腺X线摄影。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The aim of this study was to determine whether machine learning could reduce the number of mammograms the radiologist must read by using a machine-learning classifier to correctly identify normal mammograms and to select the uncertain and abnormal examinations for radiological interpretation.

METHODS: Mammograms in a research data set from over 7,000 women who were recalled for assessment at six UK National Health Service Breast Screening Program centers were used. A convolutional neural network in conjunction with multitask learning was used to extract imaging features from mammograms that mimic the radiological assessment provided by a radiologist, the patient's nonimaging features, and pathology outcomes. A deep neural network was then used to concatenate and fuse multiple mammogram views to predict both a diagnosis and a recommendation of whether or not additional radiological assessment was needed.

RESULTS: Ten-fold cross-validation was used on 2,000 randomly selected patients from the data set; the remainder of the data set was used for convolutional neural network training. While maintaining an acceptable negative predictive value of 0.99, the proposed model was able to identify 34% (95% confidence interval, 25%-43%) and 91% (95% confidence interval: 88%-94%) of the negative mammograms for test sets with a cancer prevalence of 15% and 1%, respectively.

CONCLUSION: Machine learning was leveraged to successfully reduce the number of normal mammograms that radiologists need to read without degrading diagnostic accuracy.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Kyono T, Gilbert FJ, van der Schaar M, et al. Improving Workflow Efficiency for Mammography Using Machine Learning. J Am Coll Radiol. 2019. PMID: 31153798. doi:10.1016/j.jacr.2019.05.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。