文献速递乳腺技术与安全US

自动乳腺超声联合或不联合计算机辅助检测的性能与阅片时间

Performance and Reading Time of Automated Breast US with or without Computer-aided Detection.
PubMed 文献 · Radiology · 2019-06-18

本回顾性研究纳入1452例女性共1485幅自动乳腺超声图像,比较无CAD、二次阅片和同步阅片三种模式下不同经验阅片者的诊断性能和阅片时间。结果显示所有阅片者平均AUC从无CAD的0.88提升至二次阅片的0.91和同步阅片的0.90;新手阅片者在无症状女性中的平均敏感度从67%提升至88%;同步阅片较无CAD和二次阅片分别缩短阅片时间16秒和27秒。

要点

  • 所有阅片者平均AUC:无CAD 0.88 vs 二次阅片0.91 vs 同步阅片0.90
  • 新手阅片者无症状女性敏感度:无CAD 67% vs 二次阅片和同步阅片均88%
  • 同步阅片每幅图像平均阅片时间较无CAD缩短16秒,较二次阅片缩短27秒

核心结论

  • CAD有助于新手阅片者在无症状女性的自动乳腺超声中提高癌症检出,同步使用CAD对所有阅片者更高效。

研究设计与样本

  • 回顾性研究,纳入2016年至2017年间1452例女性(平均年龄43.7岁,范围19-82岁)的1485幅自动乳腺超声图像,其中恶性病变282幅、良性病变695幅、健康508幅,529例(36.4%)女性无症状;3名具有1-3年超声经验的新手阅片者和3名具有5-10年超声经验的资深阅片者参与阅片。

诊断标准与关键数值

  • 所有阅片者平均AUC:无CAD模式0.88(95%CI:0.85,0.91),二次阅片模式0.91(95%CI:0.89,0.92;P < .001),同步阅片模式0.90(95%CI:0.89,0.92;P = .002);新手阅片者在无症状女性中的平均敏感度:无CAD模式67%(95%CI:63%,74%),二次阅片模式和同步阅片模式均为88%(95%CI:84%,89%)(P = .003)。

临床应用与阅片要点

  • 原作者结论认为CAD有助于新手阅片者在无症状女性的自动乳腺超声中提高癌症检出,且同步使用CAD对所有阅片者更高效。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BackgroundComputer-aided detection (CAD) systems may be used to help radiologists interpret automated breast (AB) US images. However, the optimal use of CAD with AB US has, to the knowledge of the authors, not been determined.PurposeTo compare the performance and reading time of different readers by using AB US CAD system to detect breast cancer in different reading modes.Materials and MethodsIn this retrospective study, 1485 AB US images (282 with malignant lesions, 695 with benign lesions, and 508 healthy) in 1452 women (mean age, 43.7 years; age range, 19-82 years) including 529 (36.4%) women who were asymptomatic were collected between 2016 and 2017. A CAD system was used to interpret the images. Three novice readers with 1-3 years of US experience and three experienced readers with 5-10 years of US experience were assigned to read AB US images without CAD, at a second reading (after the reader completed a full unaided interpretation), and at concurrent reading (use of CAD at the start of the assessment). Diagnostic performances and reading times were compared by using analysis of variance.ResultsFor all readers, the mean area under the receiver operating characteristic curve improved from 0.88 (95% confidence interval [CI]: 0.85, 0.91) at without-CAD mode to 0.91 (95% CI: 0.89, 0.92; P < .001) at the second-reading mode and 0.90 (95% CI: 0.89, 0.92; P = .002) at the concurrent-reading mode. The mean sensitivity of novice readers in women who were asymptomatic improved from 67% (95% CI: 63%, 74%) at without-CAD mode to 88% (95% CI: 84%, 89%) at both the second-reading mode and the concurrent-reading mode (P = .003). Compared with the without-CAD and second-reading modes, the mean reading time per volume of concurrent reading was 16 seconds (95% CI: 11, 22; P < .001) and 27 seconds (95% CI: 21, 32; P < .001) shorter, respectively.ConclusionComputer-aided detection (CAD) was helpful for novice readers to improve cancer detection at automated breast US in women who were asymptomatic. CAD was more efficient when used concurrently for all readers.© RSNA, 2019Online supplemental material is available for this article.See also the editorial by Slanetz in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Yang S, Gao X, Liu L, et al. Performance and Reading Time of Automated Breast US with or without Computer-aided Detection. Radiology. 2019. PMID: 31210612. doi:10.1148/radiol.2019181816

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。