文献速递乳腺US

三维自动乳腺超声:事实与伪像

Three-dimensional Automated Breast US: Facts and Artifacts.
PubMed 文献 · Radiographics · 2019-05-31

本文系统阐述三维自动乳腺超声(AB US)的成像原理与图像采集流程,将常见伪像按技术性、软件性、生理性及乳腺病变相关原因分类,并介绍识别与消除伪像(如区分伪像与真性异常、确认遮蔽伪像)的方法,旨在帮助放射科医生减少可预防的假阳性召回、提高判读效率。

要点

  • 掌握AB US成像原理与采集流程是识别和消除伪像的关键。
  • 将伪像分为技术性、软件性、生理性和乳腺病变相关四类有助于判读。
  • 识别脱落、接触不良等伪像并与手术瘢痕、可疑病变区分,可减少可预防的假阳性判读。

核心结论

  • 熟悉AB US伪像的常见模式及其分类,并采用系统方法识别与消除伪像,有助于放射科医生减少可预防的假阳性建议并提高AB US图像判读效率。

研究设计与样本

  • 本文为综述性文章,介绍AB US伪像的系统识别方法、遮蔽伪像的分析、伪像与真性异常的鉴别,以及典型模式和消除伪像的基本技术。

关键影像表现/征象

  • AB US伪像可表现为遮蔽、脱落及接触不良等,需与手术瘢痕和可疑病变等真性异常相区分。
  • 伪像按原因可分为技术性、软件性、生理性和乳腺病变相关四类。

临床应用与阅片要点

  • 可应用第二视图、附加平面及旋转工具等软件相关工具确认遮蔽为伪像。
  • 将AB US伪像按技术性、软件性、生理性和乳腺病变相关原因分类,有助于图像判读。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

As automated breast (AB) US becomes more integrated into the daily practice of breast imaging, the need to address the artifacts that interfere with AB US image interpretation is becoming more important. Learning methods to detect and subsequently resolve artifacts such as shadowing can enhance the reader's confidence and ability to differentiate artifacts and true abnormalities. Understanding the basic principles of AB US and its image acquisition process are key elements in resolving artifacts. Gaining familiarity with the common patterns of AB US artifacts and placing them into categories of technical, software, physiologic, and breast lesion-related causes can aid in image interpretation. Recognizing specific artifacts, such as dropout and lack of contact, and the ability to distinguish them from true abnormalities, such as surgical scars and suspicious lesions, can help minimize preventable false-positive interpretations. Applying methods to confirm shadowing as artifactual, including the use of a second view, additional planes, and software-related tools such as the rotational tool, can aid the radiologist in resolving artifacts and avoiding preventable recalls, potentially resulting in increased specificity. Presented is a methodical approach to recognizing AB US artifacts and their causes; analyzing shadowing, a challenging entity in the interpretation of AB US imaging studies; differentiating artifact from true abnormality; and reviewing characteristic patterns and basic techniques to resolve artifacts. The goal of this article is to enable the radiologist in applying these methods to help reduce preventable false-positive recommendations and increase efficiency in AB US image interpretation. Online supplemental material is available for this article. ©RSNA, 2019.

来源:Radiographics,查看原文。版权归原作者所有。

引用

  1. Karst I, Henley C, Gottschalk N, et al. Three-dimensional Automated Breast US: Facts and Artifacts. Radiographics. 2019. PMID: 31150298. doi:10.1148/rg.2019180104

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。