用于胎儿MRI羊水体积量化的新型计算机分析技术
本研究开发并评估一种在胎儿MRI中量化羊水体积的计算机分析技术,用含已知羊水量的MRI体模和20例临床胎儿MRI(3D稳态自由进动序列,1.5-T)进行验证。计算机测量与体模已知量无显著差异(p>0.11),与手工测量高度一致(组内相关系数0.995,p<0.01),平均完成时间110秒。
要点
- 计算机自动测量羊水体积与体模已知量无显著差异(p>0.11),与手工测量组内相关系数0.995(p<0.01)。
- 临床胎儿MRI中自动测量羊水体积平均耗时110秒,两名软件使用者与手工测量间可靠性极好。
- 该技术有望实现胎儿MRI羊水体积的客观评估,可能改善产前诊断与管理。
核心结论
- 本研究的计算机分析技术能快速、准确地量化胎儿MRI中的羊水体积,结果与体模已知体积及手工测量一致,有望用于羊水体积的客观MRI评估并可能改善产前诊断与管理。
研究设计与样本
- 开发并评估计算机分析技术的研究,使用两个含已知量合成羊水的MRI体模和20例临床胎儿MRI检查,采用1.5-T MRI的3D稳态自由进动序列,以手工描迹法作为对照,回顾性计算羊水体积并记录完成时间。
诊断标准与关键数值
- 计算机生成测量与体模已知羊水体积比较无显著差异(p>0.11)。
- 计算机生成测量与手工测量之间总羊水体积的组内相关系数为0.995(p<0.01)。
- 临床MRI检查中羊水体积测量的平均完成时间为110秒。
临床应用与阅片要点
- 作者认为该技术有望用于胎儿MRI羊水体积的客观评估,并可能改善产前诊断与管理。
- 临床阅片时可将自动测量的羊水体积与手工描迹结果对照,二者可靠性极好(组内相关系数0.995)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. Fetal MRI is increasingly used in the evaluation of suspected congenital anomalies. Assessment of amniotic fluid volume (AFV) is crucial, but no automated quantitative technique is currently available for MRI. The purpose of this study was to develop and evaluate an analytic technique for quantifying AFV in fetal MRI. MATERIALS AND METHODS. Two MRI phantoms containing known quantities of synthetic amniotic fluid were created. A 3D steady-state free precession sequence was used for 1.5-T MRI of the phantoms and as part of a standard clinical fetal MRI protocol. Software was developed and used to retrospectively calculate AFV for the phantom and 20 clinical MRI examinations. Times to completion were recorded. AFV was also calculated by a manual hand-tracing method. To evaluate performance, paired t tests were used to compare computer-generated measurements with known phantom volumes. Intraclass correlation coefficients were calculated to assess agreement between computer-generated and manual measurements. RESULTS. There was no significant difference between computer-generated measurements of known AFV in the MRI phantoms (p > 0.11). When the software program was applied to the clinical MRI examinations, the mean time to complete AFV measurement was 110 seconds. There was excellent reliability between total AFV calculated by the two software users and by means of manual measurements (intraclass correlation coefficient, 0.995; p < 0.01). CONCLUSION. The computerized analysis evaluated in this study rapidly and accurately quantifies AFV in fetal MRI. The results are concordant with known phantom volumes and manual measurements. The technique is promising for objective MRI evaluation of AFV and has the potential to improve prenatal diagnosis and management.
引用
- Didier RA, Khrichenko D, Barrera CA, et al. Novel Computerized Analytic Technique for Quantification of Amniotic Fluid Volume in Fetal MRI. AJR Am J Roentgenol. 2019. PMID: 31237453. doi:10.2214/AJR.19.21275
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。