文献速递妇产影像技术与安全US

多中心随机试验探讨模拟超声训练对产科医生诊断准确性的影响:对经验丰富操作者的价值

Multicenter randomized trial exploring effects of simulation-based ultrasound training on obstetricians' diagnostic accuracy: value for experienced operators.
PubMed 文献 · Ultrasound Obstet Gynecol · 2020-01-01

多中心随机前后对照试验纳入70名不同临床经验的产科医生,随机分为聚焦胎儿体重扫描的模拟超声训练组或无干预组,在干预前后各完成两次足月孕妇胎儿体重估计扫描。校正临床经验后,干预组测量准确性提高31.9%(95%CI 6.9-50.1%,P=0.02),对照组无改善(相对差异13.1%,95%CI -17.9至55.9%,P=0.45),组间变化差异显著(P=0.02)且与临床经验无关(P=0.54)。

要点

  • 模拟超声训练可提高足月胎儿体重估计的准确性,干预组准确性提高31.9%(95%CI 6.9-50.1%,P=0.02)。
  • 训练效果与产科医生临床经验无关(组间变化差异P=0.02,与经验交互P=0.54)。
  • 干预组图像质量评分平均提高1.2分(95%CI 0.4-2.1,P<0.01),对照组无变化(均差0.1,95%CI -0.8至1.0,P=0.78)。

核心结论

  • 模拟超声训练提高了足月孕妇胎儿体重估计的准确性和图像质量,且不依赖于产科医生的临床经验。

研究设计与样本

  • 多中心随机前后对照实效试验,于2016年3月至2018年1月开展,70名不同临床经验的产科医生随机分为模拟超声训练组(聚焦胎儿体重扫描)或无干预组。
  • 参与者在基线时完成两次足月孕妇扫描以建立胎儿体重估计基线准确性,随访时再完成两次扫描;准确性定义为估计胎儿体重与实际出生体重之间的百分比差异;超声图像质量由两名专家评分者评定。

诊断标准与关键数值

  • 准确性定义为估计胎儿体重与实际出生体重之间的百分比差异。
  • 校正临床经验后,干预组测量准确性提高31.9%(95%CI 6.9-50.1%,P=0.02),对照组相对差异13.1%(95%CI -17.9至55.9%,P=0.45),组间变化差异显著(P=0.02)且与临床经验无关(P=0.54)。
  • 干预组图像质量评分平均提高1.2(95%CI 0.4-2.1,P<0.01),对照组平均差异0.1(95%CI -0.8至1.0,P=0.78)。
  • 使用模拟器时间与临床经验呈强负相关(r=-0.70,P=0.0001)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To explore the effects of simulation-based ultrasound training on the accuracy of fetal weight estimation in the third trimester among obstetricians with different levels of clinical experience.

METHODS: This was a multicenter, randomized pre-post-test practical trial conducted between March 2016 and January 2018. Obstetricians with different levels of clinical experience were randomized to either simulation-based ultrasound training focusing on fetal weight scans or no intervention. Participants completed two scans in pregnant women at term to establish baseline accuracy of fetal weight estimation. Another two scans were performed at follow-up. Accuracy was defined by the percentage difference between estimated fetal weight and actual birth weight. Ultrasound image quality was rated by two expert raters.

RESULTS: Seventy participants with different levels of clinical experience completed the study. Adjusting for clinical experience, the intervention group demonstrated an improvement in measurement accuracy of 31.9% (95% CI, 6.9-50.1%) (P = 0.02), whereas the control group did not improve (relative difference, 13.1% (95% CI, -17.9 to 55.9%); P = 0.45). The change in accuracy was significantly different between the groups (P = 0.02) and independent of clinical experience (P = 0.54). Image-quality scores improved by a mean of 1.2 (95% CI, 0.4-2.1) (P < 0.01) in the intervention group, with no change in the control group (mean difference, 0.1 (95% CI, -0.8 to 1.0); P = 0.78). There was a strong negative correlation between time spent using the simulator and clinical experience (r = -0.70, P = 0.0001).

CONCLUSION: Simulation-based ultrasound training improved accuracy and image quality when performing fetal weight estimation in women at term, independent of obstetricians' clinical experience. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。