文献速递儿科影像外周血管腹部US

早产新生儿出生后早期肠系膜上动脉多普勒超声与坏死性小肠结肠炎的预测

Early Doppler Ultrasound in the Superior Mesenteric Artery and the Prediction of Necrotizing Enterocolitis in Preterm Neonates.
PubMed 文献 · J Ultrasound Med · 2019-06-19

本研究为前瞻性单中心研究,纳入104例早产新生儿,在出生后12小时内血流动力学稳定时测量肠系膜上动脉血流,多普勒结果对新生儿科医生和护士保密。收缩期峰值流速和舒张期差分速度较高与坏死性小肠结肠炎风险相关,差分速度曲线下面积为0.768, cutoff值为34.835 cm/s。结论认为多普勒超声对预测坏死性小肠结肠炎有希望的价值,但需进一步研究。

要点

  • 出生后12小时内肠系膜上动脉差分速度截断值34.835 cm/s,预测坏死性小肠结肠炎敏感度0.875、特异度0.604。
  • 差分速度较高与坏死性小肠结肠炎风险显著相关,逻辑回归中比值比为1.144(95%CI 1.058-1.237,P<.01)。
  • 胎龄与肠系膜上动脉血流测量值相关,逻辑回归中胎龄比值比为0.644(95%CI 0.456-0.908,P=.012)。

核心结论

  • 本单中心研究显示多普勒超声对预测坏死性小肠结肠炎有希望的价值,但需进一步研究。

研究设计与样本

  • 前瞻性单中心研究,纳入104例早产新生儿,在出生后12小时内血流动力学稳定时测量肠系膜上动脉血流。
  • 多普勒超声结果对新生儿科医生和护士保密,记录并分析所有人口学特征、合并症和结局。

诊断标准与关键数值

  • 坏死性小肠结肠炎组收缩期峰值流速中位数54.165(四分位距42.423-68.463)cm/s vs 非坏死性小肠结肠炎组42.195(34.278-48.553)cm/s,P=.027。
  • 坏死性小肠结肠炎组差分速度中位数47.445(35.010-60.043)cm/s vs 非坏死性小肠结肠炎组32.565(27.545-39.073)cm/s,P=.020。
  • 差分速度预测坏死性小肠结肠炎的曲线下面积为0.768,敏感度0.875,特异度0.604,截断值34.835 cm/s。
  • 逻辑回归中坏死性小肠结肠炎与胎龄显著相关,比值比0.644(95%CI 0.456-0.908),P=.012。
  • 逻辑回归中坏死性小肠结肠炎与差分速度显著相关,比值比1.144(95%CI 1.058-1.237),P<.01。

局限性

  • 本单中心研究,原文结论指出需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this study was to reveal the correlation between superior mesenteric artery (SMA) blood flow in the first 12 hours of life and the risk of necrotizing enterocolitis (NEC) in preterm neonates.

METHODS: We conducted a prospective study. There were 104 preterm neonates included in our study. The SMA blood flow of each neonate was measured during the first 12 hours of life if the hemodynamic situation was stable. The results of Doppler ultrasound were confidential to the neonatologists and nurses. All of the demographics, comorbidities, and outcomes were recorded and analyzed.

RESULTS: Among all of the demographics and comorbidities, the gestational age was related to the measurements of SMA blood flow. We conducted a single-factor analysis of the occurrence of NEC, including the peak systolic velocity (PSV), end-diastolic velocity, time-averaged mean velocity, differential velocity (DV), resistive index, and pulsatility index. A higher PSV (median [interquartile range], 54.165 [42.423-68.463] versus 42.195 [34.278-48.553] cm/s; P = .027) and DV (median [interquartile range], 47.445 [35.010-60.043] versus 32.565 [27.545-39.073] cm/s; P = .020) were significantly related to the risk of NEC. In the logistic analysis including gestational age, PSV, and DV, NEC was significantly associated with gestational age (odds ratio [95% confidence interval], 0.644 [0.456-0.908]; P = .012) and DV (odds ratio [95% confidence interval], 1.144 [1.058-1.237]; P < .01). The area under the receiver operating characteristic curve for the DV was 0.768, with sensitivity 0.875 and specificity 0.604. The cutoff value of the DV was 34.835 cm/s.

CONCLUSIONS: From this single-center study, we can see the promising value of Doppler ultrasound for the prediction of NEC, but further research is needed.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Guang Y, Ying D, Sheng Y, et al. Early Doppler Ultrasound in the Superior Mesenteric Artery and the Prediction of Necrotizing Enterocolitis in Preterm Neonates. J Ultrasound Med. 2019. PMID: 31218729. doi:10.1002/jum.15064

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。