颈部肿块的产前MRI:特别关注胎儿气道评估
本研究回顾性分析23例因超声怀疑颈部肿块而进行的胎儿MRI检查,以出生后影像、手术、病理及临床结局为参考标准,评估产前MRI判断气道通畅性的效能。结果显示产前MRI检测气道通畅性的敏感度为100%(9/9),特异度80%(8/10),准确率89%(17/19),并能以几乎完美的一致性(к=0.851)识别肿块性质(23例中正确识别21例)。结论认为产前MRI在评估胎儿气道状态和诊断肿块性质方面准确性高,有助于制定分娩计划。
要点
- 产前MRI评估胎儿气道通畅性的敏感度为100%(9/9),特异度80%(8/10),准确率89%(17/19)。
- 产前MRI识别肿块性质的观察者间一致性几乎完美(к=0.851),23例中正确识别21例。
- 产前MRI可高准确度评估胎儿气道状态和肿块性质,有助于制定分娩计划。
核心结论
- 产前MRI在评估胎儿气道状态和诊断肿块性质方面表现出高准确度,有助于制定合适的分娩计划。
研究设计与样本
- 回顾性分析2001年至2016年间因二级超声怀疑颈部肿块而进行的23例胎儿MRI检查,由两名分别具有12年和2年胎儿影像经验的儿科放射科医生独立分析;以出生后影像、术后报告、组织学、尸检和临床结局为参考标准。
诊断标准与关键数值
- 产前MRI检测气道通畅性的敏感度为9/9(100%,95%CI 66-100%),特异度8/10(80%,95%CI 44-98%),准确率17/19(89%,95%CI 67-99%),阳性预测值9/11(82%,95%CI 48-98%),阴性预测值8/8(100%,95%CI 63-100%)。
- 产前MRI正确识别23个肿块中的21个(к=0.858),观察者间一致性几乎完美(к=0.851)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Prenatal magnetic resonance imaging is the best tool to visualize foetal airway.
OBJECTIVE: To evaluate the performance of MRI in the assessment of foetal airway status in the presence of a neck mass.
MATERIALS AND METHODS: Two paediatric radiologists with 12- and 2-year experience in foetal imaging retrospectively analysed 23 foetal MRI examinations, performed between 2001 and 2016, after a second-level ultrasound suspicious for presence of a neck mass. Postnatal imaging, postoperative report, histology, autopsy, and clinical outcomes were the reference standard to calculate sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of prenatal MRI in detecting airway patency. We used the Cohen к statistics to estimate the interobserver agreement. We also assessed MRI performance in the diagnosis of the mass nature.
RESULTS: We obtained data about postnatal airway status in 19 of 23 patients; prenatal MRI demonstrated a sensitivity of 9/9 [100%, 95% confidence interval (CI) 66-100%], specificity 8/10 (80%, 44-98%), accuracy 17/19 (89%, 67-99%), PPV 9/11 (82%, 48-98%), and NPV 8/8 (100%, 63-100%); the interobserver agreement was perfect. Prenatal MRI correctly identified 21 of 23 masses (к = 0.858); the interobserver agreement was almost perfect (к = 0.851).
CONCLUSION: Prenatal MRI demonstrated high accuracy in assessing foetal airway status and diagnosing mass nature, allowing proper delivery planning.
引用
- Ravelli A, Napolitano M, Rustico M, et al. Prenatal MRI of neck masses with special focus on the evaluation of foetal airway. Radiol Med. 2019. PMID: 31175537. doi:10.1007/s11547-019-01049-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。