文献速递泌尿生殖腹部MR

表观扩散系数比值与常规ADC在3-T MRI检测临床显著前列腺癌中的比较

Apparent Diffusion Coefficient (ADC) Ratio Versus Conventional ADC for Detecting Clinically Significant Prostate Cancer With 3-T MRI.
PubMed 文献 · AJR Am J Roentgenol · 2019-06-19

该回顾性研究纳入218例男性240个单侧前列腺癌病灶,以全标本病理为参考,比较ADC比值与常规ADC鉴别低级别(GS 3+3)与高级别(GS≥3+4)前列腺癌的效能。ADC比值平均值的AUC为0.80,高于ADC肿瘤平均值的0.70和ADC肿瘤最小值的0.67(p=0.043),在移行带优势更明显。

要点

  • ADC比值平均值鉴别低级别与高级别前列腺癌的AUC为0.80,优于常规ADC肿瘤平均值(0.70)。
  • 移行带ADC比值平均值AUC为0.87,显著高于ADC肿瘤平均值(0.63,p=0.019)。
  • 外周带ADC比值平均值AUC为0.78,与ADC肿瘤平均值(0.74)差异无统计学显著(p=0.44)。

核心结论

  • 作为患者内归一化诊断工具,ADC比值在3-T MRI上鉴别低级别与高级别前列腺癌时提供了最高的AUC值。

研究设计与样本

  • 回顾性研究,纳入218例男性共240个单侧前列腺癌病灶,均行3-T多参数MRI和全标本病理分析。
  • 以全标本病理为参考标准,在病理证实的病灶及对侧非肿瘤区域放置ROI,计算ADC肿瘤平均值、ADC肿瘤最小值、ADC良性背景值及ADC比值。

诊断标准与关键数值

  • ADC比值平均值鉴别GS 3+3与GS≥3+4前列腺癌的AUC为0.80,ADC比值最小值为0.72。
  • ADC肿瘤平均值AUC为0.70,ADC肿瘤最小值AUC为0.67。
  • 移行带ADC比值平均值AUC为0.87,ADC肿瘤平均值AUC为0.63(p=0.019)。
  • 外周带ADC比值平均值AUC为0.78,ADC肿瘤平均值AUC为0.74(p=0.44)。

临床应用与阅片要点

  • ADC比值平均值可作为患者内归一化指标,用于辅助鉴别低级别与高级别前列腺癌。
  • 在移行带病灶中,ADC比值平均值较常规ADC肿瘤平均值显示出更高的鉴别效能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study is to evaluate the performance of the apparent diffusion coefficient ratio (ADCratio; the ADC of the suspected prostate cancer [PCa] focus on MRI divided by the ADC in a noncancerous reference area) with that of conventional ADC for detection of high-grade PCa (Gleason score [GS] ≥ 3 + 4) versus low-grade PCa (GS = 3 + 3) with whole-mount (WM) histopathologic analysis used as a reference. MATERIALS AND METHODS. The cohort of this retrospective study included 218 men with 240 unilateral PCa lesions assessed by both 3-T multiparametric MRI and whole-mount histopathologic analysis. ROIs were placed on individual lesions verified by WM histopathologic analysis, to calculate the mean ADC (ADCtumor_mean) and lowest ADC within each lesion (ADCtumor_min), and within non-tumor-containing regions of the same tumor zone but on the contralateral side (ADCbenign), to calculate the background ADC. The ADCratio_mean (the ADCtumor_mean divided by the ADCbenign) was calculated. The performance of individual ADCtumor and ADCratio_mean values in discriminating PCa with a GS of 3 + 3 from PCa with a GS of 3 + 4 or greater was assessed using the AUC value. RESULTS. The ADCratio_mean had a higher AUC value for discriminating PCa lesions with a GS of 3 + 3 from those with a GS of 3 + 4 or greater (the AUC value increased from 0.70 using the ADCtumor_mean and 0.67 using the ADCtumor_min [the minimum ADC of the PCa lesion] to 0.80 for the ADCratio_mean and 0.72 for the ADCratio_min [the ADCtumor_min divided by the ADCbenign]; p = 0.043). When stratified by PCa zonal location, the ADCratio_mean had significantly more robust accuracy in the transition zone (the AUC value increased from 0.63 for ADCtumor_mean to 0.87 for ADCratio_mean; p = 0.019) compared with the peripheral zone (the AUC value increased from 0.74 for ADCtumor_mean to 0.78 for ADCratio_mean; p = 0.44). When analyzed on the basis of endorectal coil use, the ADCratio_mean performed nonsignificantly better in both the endorectal coil and non-endorectal coil subcohorts, although it performed better in the former. CONCLUSION. As an intrapatient-normalized diagnostic tool, the ADC ratio provided the best AUC value for discrimination of low-grade from high-grade PCa on 3-T MRI.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Bajgiran AM, Mirak SA, Sung K, et al. Apparent Diffusion Coefficient (ADC) Ratio Versus Conventional ADC for Detecting Clinically Significant Prostate Cancer With 3-T MRI. AJR Am J Roentgenol. 2019. PMID: 31216201. doi:10.2214/AJR.19.21365

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。