文献速递泌尿生殖技术与安全MR

前列腺多参数MRI实施与报告的区域标准化:前列腺影像主管是否有作用?

Regional Standardization of Prostate Multiparametric MRI Performance and Reporting: Is There a Role for a Director of Prostate Imaging?
PubMed 文献 · AJR Am J Roentgenol · 2019-06-10

研究评估四家外周机构(五台1.5-T系统)前列腺多参数MRI在前列腺影像主管干预前后的技术参数与报告情况,并与区域学术转诊中心(3-T系统)及PI-RADSv2技术规范比较。干预后外周系统对PI-RADSv2技术规范的依从性提高,提供PI-RADSv2评分的中心从一家增至全部四家。

要点

  • 干预后T2WI空间分辨率依从性从40%(五台系统中两台)升至100%(全部五台)(p=0.038)。
  • 干预后DWI空间分辨率依从性从20%升至100%,仅一家外周中心基线提供PI-RADSv2评分,干预后四家均提供(p=0.028)。
  • 转诊中心除DWI空间分辨率不足外,完全符合PI-RADSv2技术规范。

核心结论

  • 前列腺影像主管可能推动特定地理区域内前列腺MRI实施与报告的标准化。

研究设计与样本

  • 研究类型为干预前后比较,对象为四家外周机构(五台1.5-T系统)的前列腺mpMRI检查,并与区域学术转诊中心(3-T系统)及PI-RADSv2技术规范比较。
  • 分析DICOM头文件中的T2加权、DWI和动态对比增强技术参数,由一名盲法放射科医生将报告与转诊中心及PI-RADSv2技术规范比较。
  • 在前列腺影像主管干预后重新评估数据,比较采用卡方分析。

诊断标准与关键数值

  • 外周系统T2WI空间分辨率依从性从基线40%(五台系统中两台)升至干预后100%(全部五台)(p=0.038)。
  • 外周系统DWI空间分辨率依从性从20%升至100%。
  • 1.5 T下改善图像质量的改良DWI空间分辨率依从性(矩阵100×100;FOV 28×28 cm;层厚4 mm)从60%(b值≥1400 s/mm²)升至100%(p=0.114)。
  • 动态对比增强成像空间分辨率依从性从60%升至100%(p=0.114),时间分辨率依从性(≤10秒)从20%升至100%(p=0.10),采集时间依从性(≥2分钟)从60%升至100%(p=0.114)。
  • 四家外周中心中仅一家基线提供PI-RADSv2评分,干预后全部四家均提供(p=0.028)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study was to assess prostate multiparametric MRI (mpMRI) before and after intervention by a director of prostate imaging. MATERIALS AND METHODS. Images from prostate mpMRI examinations at four peripheral institutions (five 1.5-T systems) were studied. DICOM headers were analyzed for T2-weighted, DWI, and dynamic contrast-enhanced technical specifications. Reports were retrieved, and a blinded radiologist compared them with those from the regional academic referral center (3-T system) and Prostate Imaging and Data Reporting System version 2 (PI-RADSv2) technical specifications. Data were reevaluated after intervention by a director of prostate imaging. Comparisons were performed by chi-square analysis. RESULTS. Except for having insufficient DWI spatial resolution, the referral center fully complied with PI-RADSv2. For peripheral systems, compliance with PI-RADSv2 technical specifications improved from baseline to after intervention. For T2-weighted imaging, compliance with spatial resolution increased from 40% (two of five MRI systems) to 100% (all five systems) (p = 0.038). For DWI, spatial resolution compliance increased from 20% to 100%. For modified DWI, spatial resolution compliance to improve image quality at 1.5 T (matrix, 100 × 100; FOV, 28 × 28 cm; slice thickness, 4 mm) increased from 60% (b value ≥ 1400 s/mm2) to 100% (p = 0.114). For dynamic contrast-enhanced imaging, spatial resolution compliance increased from 60% to 100% (p = 0.114), temporal resolution compliance increased from 20% (≤ 10 seconds) to 100% (p = 0.10), and acquisition time compliance increased from 60% (≥ 2 minutes) to 100% (p = 0.114). Only one of the four peripheral centers provided PI-RADSv2 scores, but all of them did after the intervention (p = 0.028). CONCLUSION. A director of prostate imaging may drive standardization of prostate MRI performance and reporting within specified geographic regions.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Abreu-Gomez J, Shabana W, McInnes MDF, et al. Regional Standardization of Prostate Multiparametric MRI Performance and Reporting: Is There a Role for a Director of Prostate Imaging? AJR Am J Roentgenol. 2019. PMID: 31180739. doi:10.2214/AJR.19.21111

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。