研究纳入28名成人志愿者(无肾积水13例、低级别肾积水8例、高级别肾积水7例),以双血浆样本法测得的GFR为参考标准,比较DCE-MRR与肾闪烁显像所测GFR的准确性和一致性。结果显示两种方法在肾积水患者中均高估GFR,DCE-MRR与RS相关性良好且观察者间信度良好,DCE-MRR可能作为无创替代方法用于GFR测量。
要点
- 在肾积水患者中,DCE-MRR高估GFR约12.8±13.9 mL/min,RS高估约11.5±12.3 mL/min。
- 高级别肾积水肾脏中,RS所测单肾GFR比DCE-MRR所测单肾GFR高5.7±3.8 mL/min(p=0.004)。
- DCE-MRR与RS的单肾GFR观察者间信度均良好(ICC分别为0.82-0.92和0.79-0.90)。
核心结论
- DCE-MRR与RS在肾积水患者中均倾向于高估GFR。
- 在高级别肾积水肾脏中,RS所测单肾GFR略高于DCE-MRR所测单肾GFR。
- DCE-MRR与RS相当,可能作为无创替代方法用于GFR测量。
研究设计与样本
- 研究纳入28名成人志愿者:无肾积水13例、低级别肾积水8例、高级别肾积水7例。
- 以双血浆样本法测得的GFR(GFRRef)为参考标准。
- 比较DCE-MRR所测GFR(GFRMRR)与肾闪烁显像所测GFR(GFRRS)同GFRRef的相关性和一致性。
- 评估单肾GFRMRR(skGFRMRR)与单肾GFRRS(skGFRRS)的相关性及两种方法的观察者间信度。
诊断标准与关键数值
- 在肾积水患者中,DCE-MRR高估GFR 12.8±13.9 mL/min(均值±标准差)。
- 在肾积水患者中,RS高估GFR 11.5±12.3 mL/min(均值±标准差)。
- 高级别肾积水肾脏中,skGFRRS比skGFRMRR高5.7±3.8 mL/min(p=0.004)。
- skGFRMRR的观察者间信度ICC=0.82-0.92,skGFRRS的观察者间信度ICC=0.79-0.90,均覆盖无肾积水与肾积水肾脏。
- 三名研究者重复测量的总体平均标准差:skGFRMRR为4.0 mL/min,skGFRRS为3.8 mL/min。
临床应用与阅片要点
- DCE-MRR与RS在肾积水患者中均倾向于高估GFR,阅片报告GFR时需结合肾积水程度解读。
- 高级别肾积水肾脏中RS所测单肾GFR略高于DCE-MRR,两者单肾GFR结果不可直接互换。
- 作者认为DCE-MRR与RS相当,可能作为无创替代方法用于GFR测量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The objective of our study was to assess the accuracy of glomerular filtration rate (GFR) evaluation in patients with obstructive hydronephrosis using dynamic contrast-enhanced MR renography (DCE-MRR). MATERIALS AND METHODS. A group of 28 adult volunteers were enrolled in this study: 13 without hydronephrosis, eight with low-grade hydronephrosis, and seven with high-grade hydronephrosis. The GFR obtained from DCE-MRR (GFRMRR) and the GFR obtained from renal scintigraphy (GFRRS) were compared with the reference GFR (GFRRef) acquired using the two plasma sample method. The correlation and agreement between GFRMRR and GFRRef, GFRRS and GFRRef, and single-kidney GFRMRR (skGFRMRR) and single-kidney GFRRS (skGFRRS) were assessed. The interrater reliability of DCE-MRR and the interrater reliability of renal scintigraphy (RS) were measured. RESULTS. Both GFRMRR and GFRRS correlated well with GFRRef. In patients with hydronephrosis, DCE-MRR and RS overestimated GFR by 12.8 ± 13.9 mL/min (mean ± SD) and 11.5 ± 12.3 mL/min, respectively. The skGFRRS was higher than skGFRMRR by 5.7 ± 3.8 mL/min in high-grade hydronephrotic kidneys (p = 0.004). Good interrater reliability was observed for skGFRMRR (intraclass correlation coefficient [ICC] = 0.82-0.92) and skGFRRS (ICC = 0.79-0.90) for both nonhydronephrotic kidneys and hydronephrotic kidneys. The overall mean SDs of repeated measurements from three investigators were 4.0 and 3.8 mL/min for skGFRMRR and skGFRRS, respectively. CONCLUSION. Both DCE-MRR and RS tend to overestimate GFR in patients with hydronephrosis. RS-derived skGFR is slightly higher than that of DCE-MRR in kidneys with high-grade hydronephrosis. DCE-MRR is comparable to RS and may serve as an alternative noninvasive method for GFR measurement.
引用
- Wang YC, Chang D, Zhang SJ, et al. The Accuracy of Renal Function Measurements in Obstructive Hydronephrosis Using Dynamic Contrast-Enhanced MR Renography. AJR Am J Roentgenol. 2019. PMID: 31237781. doi:10.2214/AJR.19.21224
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。