基于MRI的肝脏立体定向体部放疗治疗计划:深度学习合成CT生成方法的验证
本研究将密集块整合到循环生成对抗网络中,利用21例配准CT-MR对通过留一交叉验证生成合成CT。合成CT与CT的配准误差为72.87±18.16 HU,多数靶区与危及器官剂量体积指标无显著差异(p>0.05),γ分析通过率在1%/1 mm标准下超过99%。结论认为影像相似性和剂量一致性支持进一步开发肝脏SBRT的MRI-only工作流程。
要点
- 合成CT与参考CT的HU平均绝对误差为72.87±18.16 HU,归一化互相关为0.92±0.04。
- 基于合成CT与基于CT的治疗计划在多数靶区和危及器官剂量体积指标上无显著差异(p>0.05)。
- 等中心冠状面γ分析通过率在1%/1 mm标准下平均超过99%。
核心结论
- 合成CT与原始CT之间的影像相似性和剂量学一致性支持进一步开发用于肝脏立体定向体部放疗的MRI-only工作流程。
研究设计与样本
- 研究纳入21例具有配准CT和MR图像对的患者,采用留一交叉验证评估所提出的密集块循环生成对抗网络合成CT方法。
诊断标准与关键数值
- 合成CT的平均绝对误差为72.87±18.16 HU,峰值信噪比为22.65±3.63 dB,归一化互相关为0.92±0.04;等中心冠状面γ分析在1%/1 mm标准下平均通过率超过99%。
临床应用与阅片要点
- 作者认为,该方法能够成功生成肋骨等小骨性结构,并能以与参考CT相当的精度预测用于剂量计算的HU值。
局限性
- 原文结论提出需要进一步开发MRI-only工作流程,原文用词为warrant further development。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this work is to develop and validate a learning-based method to derive electron density from routine anatomical MRI for potential MRI-based SBRT treatment planning.
METHODS: We proposed to integrate dense block into cycle generative adversarial network (GAN) to effectively capture the relationship between the CT and MRI for CT synthesis. A cohort of 21 patients with co-registered CT and MR pairs were used to evaluate our proposed method by the leave-one-out cross-validation. Mean absolute error, peak signal-to-noise ratio and normalized cross-correlation were used to quantify the imaging differences between the synthetic CT (sCT) and CT. The accuracy of Hounsfield unit (HU) values in sCT for dose calculation was evaluated by comparing the dose distribution in sCT-based and CT-based treatment planning. Clinically relevant dose-volume histogram metrics were then extracted from the sCT-based and CT-based plans for quantitative comparison.
RESULTS: The mean absolute error, peak signal-to-noise ratio and normalized cross-correlation of the sCT were 72.87 ± 18.16 HU, 22.65 ± 3.63 dB and 0.92 ± 0.04, respectively. No significant differences were observed in the majority of the planning target volume and organ at risk dose-volume histogram metrics ( p > 0.05). The average pass rate of γ analysis was over 99% with 1%/1 mm acceptance criteria on the coronal plane that intersects with isocenter.
CONCLUSION: The image similarity and dosimetric agreement between sCT and original CT warrant further development of an MRI-only workflow for liver stereotactic body radiation therapy.
ADVANCES IN KNOWLEDGE: This work is the first deep-learning-based approach to generating abdominal sCT through dense-cycle-GAN. This method can successfully generate the small bony structures such as the rib bones and is able to predict the HU values for dose calculation with comparable accuracy to reference CT images.
引用
- Liu Y, Lei Y, Wang T, et al. MRI-based treatment planning for liver stereotactic body radiotherapy: validation of a deep learning-based synthetic CT generation method. Br J Radiol. 2019. PMID: 31192695. doi:10.1259/bjr.20190067
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。