利用双能CT虚拟平扫图像评估胆系结石病:虚拟平扫图像在胆系结石检测方面可替代真实平扫图像
本研究回顾性纳入2017年3月至2018年4月间75例疑似胆系疾病并于CT后2个月内接受手术和/或内镜介入的患者,比较双源双能CT虚拟平扫与真实平扫检测胆结石和胆总管结石的敏感度与特异度并计算辐射剂量降低幅度。结果显示两种图像检测胆结石及胆总管结石的敏感度与特异度均无显著差异(P > 0.05),省略真实平扫预计可降低辐射剂量22.4 ± 1.3%。作者认为虚拟平扫图像与真实平扫图像相当,可能替代真实平扫以减少辐射剂量。
要点
- 虚拟平扫与真实平扫检测胆结石及胆总管结石的敏感度、特异度无显著差异(P > 0.05)。
- 省略真实平扫预计可降低辐射剂量22.4 ± 1.3%。
- 作者认为虚拟平扫可替代真实平扫以减少辐射剂量。
核心结论
- 双能CT虚拟平扫图像在胆系结石检测方面与真实平扫图像相当,可能替代真实平扫以减少辐射剂量。
研究设计与样本
- 回顾性研究,2017年3月至2018年4月纳入75例疑似胆系疾病患者,均接受双源双能CT检查并在CT后2个月内接受手术和/或内镜介入。
诊断标准与关键数值
- 胆结石检测:真实平扫敏感度90.7%(39/43)、特异度87.5%(28/32);虚拟平扫敏感度88.4%(38/43)、特异度90.6%(29/32)。
- 胆总管结石检测:真实平扫敏感度87.5%(7/8)、特异度98.5%(66/67);虚拟平扫敏感度75.0%(6/8)、特异度100%(67/67)。
- 两种图像检测胆结石及胆总管结石的敏感度与特异度均无显著差异(P > 0.05)。
- 省略真实平扫预计辐射剂量降低22.4 ± 1.3%。
临床应用与阅片要点
- 作者认为虚拟平扫图像可替代真实平扫用于胆系结石检测,以减少辐射剂量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the virtual non-contrast (VNC) images acquired through dual-energy computed tomography (DECT) with the true non-contrast (TNC) images in the detection of biliary stones and to calculate dose reduction by replacing TNC images with VNC images.
METHODS: Between March 2017 and April 2018, we retrospectively enrolled 75 patients with suspicious biliary disease who underwent dual-source DECT and surgery and/or endoscopic intervention within 2 months from the CT. Biliary stones were present in 45 patients. The sensitivity and specificity for detecting gallstone and common bile duct (CBD) stone were compared between the VNC and TNC using McNemar test. In addition, the possible reduction in radiation dose was calculated.
RESULTS: In our study, 37 patients had gallstones, 2 had CBD stones, and 6 had both gallstone and CBD stones. For detection of gallstones, the sensitivity and specificity were 90.7% (39/43) and 87.5% (28/32), respectively, for the TNC images, and 88.4% (38/43) and 90.6% (29/32), respectively, for the VNC images. With respect to CBD stones, the sensitivity and specificity were 87.5% (7/8) and 98.5% (66/67), respectively, for the TNC images, and 75.0% (6/8) and 100% (67/67), respectively, for the VNC images. There was no significant difference in the sensitivity and specificity between each image set (P > 0.05). The radiation dose reduction of 22.4 ± 1.3% is expected by omitting TNC images.
CONCLUSIONS: The VNC images derived from DECT were comparable to the TNC images for the detection of biliary stones and may replace the TNC images to reduce radiation dose.
引用
- Bae JS, Lee DH, Joo I, et al. Utilization of virtual non-contrast images derived from dual-energy CT in evaluation of biliary stone disease: Virtual non-contrast image can replace true non-contrast image regarding biliary stone detection. Eur J Radiol. 2019. PMID: 31153571. doi:10.1016/j.ejrad.2019.04.008