文献速递腹部儿科影像MR

儿童及青少年接受钆塞酸二钠增强肝脏磁共振成像时的呼吸运动

Respiratory motion in children and young adults undergoing liver magnetic resonance imaging with intravenous gadoxetate disodium contrast material.
PubMed 文献 · Pediatr Radiol · 2019-06-16

该回顾性队列研究纳入2010年10月至2018年1月间130例≤18岁接受钆塞酸二钠动态肝脏MR检查的儿童,由三名儿科放射科医生用5分Likert量表评分各期呼吸运动伪影。清醒组各期平均运动评分差异有统计学意义(P<0.0001),动脉期运动评分(均值3.52±0.83)显著高于其他各期(P≤0.0003);全麻组各期差异无统计学意义(P=0.051)。结论提示清醒儿童接受钆塞酸二钠动态肝脏MR时动脉期呼吸运动伪影显著增加,全麻可能抑制该现象。

要点

  • 清醒儿童钆塞酸二钠增强肝脏MR动脉期呼吸运动伪影评分显著高于其他期(P≤0.0003)。
  • 全麻儿童各期运动评分差异无统计学意义(P=0.051),全麻可能抑制该现象。
  • 清醒组中未发现动脉期运动评分的显著患者特异性预测因素。

核心结论

  • 清醒儿童接受钆塞酸二钠动态肝脏MR时动脉期呼吸运动伪影显著增加,提示儿童中可发生一过性呼吸运动;全麻可能抑制该现象。

研究设计与样本

  • 回顾性队列研究,经机构审查委员会批准并豁免知情同意,纳入130例≤18岁患儿(50%[n=65]为女性,平均年龄9.8±3.7岁,48.5%[n=63]为清醒状态),于2010年10月至2018年1月接受钆塞酸二钠动态肝脏MR检查,由三名儿科放射科医生用5分Likert量表对所有成像期相评分。

关键影像表现/征象

  • 运动伪影按5分Likert量表评分,清醒组各期平均运动评分差异有统计学意义(P<0.0001)。
  • 清醒组动脉期运动评分(均值3.52±0.83)显著高于其他所有期相的平均运动评分(P≤0.0003)。
  • 全麻组各期平均运动评分差异无统计学意义(P=0.051)。

诊断标准与关键数值

  • 呼吸运动伪影采用5分Likert量表评分,由三名儿科放射科医生对所有成像期相评分。
  • 清醒组动脉期运动评分均值3.52±0.83,显著高于其他期相(P≤0.0003)。

临床应用与阅片要点

  • 清醒儿童接受钆塞酸二钠动态肝脏MR时,阅片需注意动脉期呼吸运动伪影可能较重。
  • 全麻状态下各期运动评分差异无统计学意义(P=0.051),全麻可能抑制该一过性呼吸运动现象。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Gadoxetate disodium, utilized in hepatobiliary magnetic resonance (MR) imaging, has been associated with transient respiratory motion during the arterial phase in adults.

OBJECTIVE: The purpose of this study was to determine the presence and severity of this phenomenon in children imaged awake versus under general anesthesia.

MATERIALS AND METHODS: This retrospective cohort study was approved by the institutional review board; informed consent was waived. One hundred thirty exams of children ≤18 years old who underwent dynamic liver MR imaging with gadoxetate disodium between October 2010 and January 2018 were reviewed. Three pediatric radiologists scored respiratory motion artifacts on all imaging phases using a 5-point Likert scale. Differences in mean motion scores were assessed with analysis of variance and Tukey's multiple comparisons test, and multivariable regression was used to identify predictors of arterial phase motion in awake patients.

RESULTS: One hundred thirty patients (50% [n=65] female; mean age: 9.8±3.7 years, 48.5% [n=63] awake) were included. There were significant differences in mean motion scores between phases in the awake cohort (P<0.0001) but not in the general anesthesia cohort (P=0.051). In the awake cohort, arterial phase motion score (mean: 3.52±0.83) was significantly higher than mean motion score in all other phases (P≤0.0003). There were no significant patient-specific predictors of arterial phase motion score in the awake cohort.

CONCLUSION: Significantly increased arterial phase respiratory motion artifact in awake children undergoing dynamic liver MR imaging with gadoxetate disodium suggests that transient respiratory motion occurs in children. General anesthesia may suppress this phenomenon.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Gilligan LA, Trout AT, Anton CG, et al. Respiratory motion in children and young adults undergoing liver magnetic resonance imaging with intravenous gadoxetate disodium contrast material. Pediatr Radiol. 2019. PMID: 31203405. doi:10.1007/s00247-019-04437-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。