学术医疗中心腹部CT和MRI检查中技师分配协议的效率与准确性:对医师工作量的意义
本质量改进项目在大型学术医疗中心由2名CT和2名MRI技师在15周内分配腹部CT和MRI检查协议,评估其效率与准确性。技师每小时分配协议数CT为22、MRI为19(p=0.28);技师分配协议占CT检查33.9%、MRI检查23.8%(p<0.001);放射科医师质控报告CT仅0.18%、MRI仅0.88%;随机抽查80份协议全部正确。结论认为技师可高效准确分配协议。
要点
- CT技师每小时分配协议22个,MRI技师19个,两者差异无统计学意义(p=0.28)。
- 技师分配协议占CT检查33.9%、MRI检查23.8%,CT比例高于MRI(p<0.001)。
- 放射科医师对技师分配协议的质控报告率CT为0.18%、MRI为0.88%(p=0.017)。
核心结论
- 在学术医疗中心,技师能够高效且准确地为腹部CT和MRI检查分配协议,使放射科医师有更多时间从事其他增值活动。
研究设计与样本
- 本质量改进项目在大型学术医疗中心开展,由2名CT技师和2名MRI技师在15周研究期内分配检查协议。
- 主要结局指标为技师每小时分配协议的平均数;次要结局指标为技师分配协议的检查比例及技师完成协议的质控报告归档率。
- 采用双尾t检验比较平均协议数,采用卡方检验比较CT与MRI之间的比例。
诊断标准与关键数值
- 技师每小时分配协议平均数:CT为22/h,MRI为19/h(p=0.28)。
- 技师分配协议占比:CT为1650/4867(33.9%,每周范围23-275),MRI为569/2388(23.8%,每周范围0-95)(p<0.001)。
- 放射科医师对不准确协议的质控报告:CT为3/1650(0.18%),MRI为5/569(0.88%)(p=0.017)。
- 随机抽取的CT和MRI协议回顾未发现错误(80/80正确)。
- 无患者因协议错误被召回重复成像。
临床应用与阅片要点
- 原文结论认为技师可高效准确分配腹部CT和MRI检查协议,使放射科医师有更多时间从事其他增值活动。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to evaluate the technologist productivity and accuracy in assigning protocols for abdominal CT and MRI examinations compared with a standard work flow whereby protocols are assigned by physicians. MATERIALS AND METHODS. In this quality improvement project at a large academic medical center, two CT technologists and two MRI technologists assigned protocols for examinations during a 15-week study period. The primary outcome measure was mean number of protocols assigned by technologists per hour. Secondary outcome measures were proportion of examinations with protocols assigned by technologists and rate of filing of quality assurance reports for protocols completed by technologists. A two-tailed t test was used to compare mean number of protocols; a chi-square test was used to compare proportions between CT and MRI. RESULTS. The mean number of protocols assigned by technologists per hour was not different between CT and MRI (CT, 22/h; MRI, 19/h; p = 0.28). CT and MRI technologist protocols accounted for 1650 of 4867 (33.9%) CT examinations (range, 23-275 per week) and 569 of 2388 (23.8%) MRI examinations (range, 0-95 per week) (p < 0.001). Radiologist quality assurance reports on inaccurate protocols were rare: three for CT (3/1650 [0.18%]), five for MRI (5/569 [0.88%]) (p = 0.017). A retrospective review of randomly selected CT and MRI protocols revealed no errors (80/80 correct). No patients were called back for repeat imaging due to protocol error. CONCLUSION. Technologists can efficiently and accurately assign protocols for abdominal CT and MRI examinations at an academic medical center, leading to increased radiologist time spent on other value-added activities.
引用
- Glazer DI, Alper DP, Lee LK, et al. Technologist Productivity and Accuracy in Assigning Protocols for Abdominal CT and MRI Examinations at an Academic Medical Center: Implications for Physician Workload. AJR Am J Roentgenol. 2019. PMID: 31216200. doi:10.2214/AJR.19.21353
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。