两点法用于粘弹性材料剪切波相速度频散稳健估计
该文提出一种仅利用两个侧向位置测量的剪切波数据、基于复Morlet小波变换的剪切波相速度频散估计方法(2P-CWT),并与二维傅里叶变换(2D-FT)对比。在加入与未加入高斯白噪声的粘弹性介质数字体模、自制组织模拟粘弹性体模实验及离体猪肝测量中,2P-CWT在更宽频带内提供误差更低的频散曲线估计,在仿真结果中准确度更好,可用于测量粘弹性材料的相速度。
要点
- 2P-CWT仅需两个侧向位置的剪切波测量,即可估计粘弹性材料的相速度频散曲线。
- 与2D-FT相比,2P-CWT在更宽频带内频散曲线估计误差更低。
- 该方法在数字体模、组织模拟体模及离体猪肝数据上进行了测试。
核心结论
- 2P-CWT在更宽频带内提供比2D-FT误差更低的频散曲线估计。
- 测试显示两点技术在仿真结果中准确度更好,可用于测量粘弹性材料的相速度。
研究设计与样本
- 方法学研究:提出基于复Morlet小波变换的2P-CWT,仅利用两个侧向位置的剪切波测量进行频散估计。
- 在采用局部相互作用仿真方法(LISA)生成的粘弹性介质数字体模数据上测试,包括加入与未加入高斯白噪声的波运动。
- 在自制组织模拟粘弹性体模实验数据及离体猪肝测量数据上测试,并与2D-FT技术比较。
关键影像表现/征象
- 2P-CWT与2D-FT相比,在更宽频带内频散曲线估计误差更低。
- 两点技术(2P-CWT)在仿真结果中准确度更好。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Ultrasound shear wave elastography (SWE) is an imaging modality used for noninvasive, quantitative evaluation of tissue mechanical properties. SWE uses an acoustic radiation force to produce laterally propagating shear waves that can be tracked in spatial and temporal domains in order to obtain the wave velocity. One of the ways to study the viscoelasticity is through examining the shear wave velocity dispersion curves. In this paper, we present an alternative method to two-dimensional Fourier transform (2D-FT). Our unique approach (2P-CWT) considers shear wave propagation measured in two lateral locations only and uses wavelet transformation analysis. We used the complex Morlet wavelet function as the mother wavelet to filter two shear waves at different locations. We examined how the first signal position and the distance between the two locations affect the shear wave velocity dispersion estimation in 2P-CWT. We tested this new method on a digital phantom data created using the local interaction simulation approach (LISA) in viscoelastic media with and without added white Gaussian noise to the wave motion. Moreover, we tested data acquired from custom made tissue mimicking viscoelastic phantom experiments and ex vivo porcine liver measurements. We compared results from 2P-CWT with the 2D-FT technique. 2P-CWT provided dispersion curves estimation with lower errors over a wider frequency band in comparison to 2D-FT. Tests conducted showed that the two-point technique gives results with better accuracy in simulation results and can be used to measure phase velocity of viscoelastic materials.
引用
- Kijanka P, Ambrozinski L, Urban MW, et al. Two Point Method For Robust Shear Wave Phase Velocity Dispersion Estimation of Viscoelastic Materials. Ultrasound Med Biol. 2019. PMID: 31230912. doi:10.1016/j.ultrasmedbio.2019.04.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。