文献速递心血管CT

基于冠状动脉CT血管造影的无创血流储备分数对病变特异性缺血的诊断效能:多中心研究与Meta分析

Diagnostic performance of fractional flow reserve derived from coronary CT angiography for detection of lesion-specific ischemia: A multi-center study and meta-analysis.
PubMed 文献 · Eur J Radiol · 2019-04-23

该多中心研究在136例患者183支血管中以有创血流储备分数(FFR)为参考标准,评估基于机器学习算法的CT-FFR(cFFRML)诊断效能,并纳入文献进行Meta分析。cFFRML在每支血管水平的敏感度、特异度、准确率分别为0.85、0.94、0.90;Meta分析汇总CT-FFR的AUC为0.86(95%CI 0.83~0.89),高于CCTA的0.83(95%CI 0.79~0.86)。作者结论认为CT-FFR对缺血特异性病变及中等病变具有高诊断准确率。

要点

  • CT-FFR以有创FFR为参考标准,每支血管水平的汇总敏感度0.85、特异度0.82、准确率0.82,AUC 0.86。
  • cFFRML对中等病变的敏感度、特异度、准确率分别为0.84、0.92、0.89。
  • 不同CT-FFR算法之间的联合诊断效能与有创FFR比较无显著差异(原文报告P < 0.001)。

核心结论

  • 多中心研究联合Meta分析显示,CT-FFR在判断缺血特异性病变及中等病变方面具有高诊断准确率。
  • 以有创FFR为参考标准时,不同CT-FFR算法的联合诊断效能比较无显著差异(原文报告P < 0.001)。

研究设计与样本

  • 研究类型为多中心研究联合Meta分析,来自四个中心的136例患者共183支血管纳入多中心研究。
  • 多中心研究采用基于机器学习算法的CT-FFR(cFFRML),以有创FFR为参考标准。
  • Meta分析检索Web of Science、PubMed、Cochrane图书馆,纳入比较CCTA与CT-FFR诊断效能的研究。
  • 诊断效能按每支血管和每位患者水平、针对中等病变及按算法分别分析。

诊断标准与关键数值

  • 多中心研究中,cFFRML每支血管水平的敏感度0.85、特异度0.94、准确率0.90;CCTA分别为0.95、0.28、0.55。
  • Meta分析中,CT-FFR每支血管水平的汇总敏感度0.85、特异度0.82、准确率0.82,AUC 0.86(95%CI 0.83~0.89)。
  • Meta分析中,CCTA每支血管水平的汇总敏感度0.85、特异度0.57、准确率0.65,AUC 0.83(95%CI 0.79~0.86)。
  • cFFRML对中等病变的敏感度0.84、特异度0.92、准确率0.89。

临床应用与阅片要点

  • 原文结论认为CT-FFR对缺血特异性病变和中等病变具有高诊断准确率,可供日常阅片参考。
  • 原文指出不同CT-FFR算法之间与有创FFR比较的联合诊断效能无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the diagnostic performance of coronary computed tomography angiography derived fractional flow reserve (CT-FFR) with invasive fractional flow reserve (FFR) in patients with coronary artery disease" before "with invasive fractional flow reserve serving as the reference standard.

MATERIALS AND METHODS: CT-FFR values based on a machine learning algorithm (cFFRML) in 183 vessels of 136 patients from four centers were measured with invasive FFR as reference standard. The diagnostic performance from our multicenter study was combined into a meta-analysis following a literature search in Web of Science, PubMed, Cochrane library to identify studies comparing diagnostic performance of coronary computed tomography angiography (CCTA) and CT-FFR. Sensitivity, specificity, accuracy were analyzed on both per-vessel and per-patient basis for intermediate lesions and by algorithm.

RESULTS: Our multicenter study demonstrated sensitivities, specificities, and accuracies of cFFRML and CCTA of 0.85, 0.94, 0.90, and 0.95, 0.28, 0.55 on a per-vessel basis, respectively. For our meta-analysis, pooled sensitivities, specificities, and accuracies of CT-FFR and CCTA were 0.85, 0.82, 0.82, and 0.85, 0.57, 0.65 with AUC of 0.86 (95%CI: 0.83˜0.89) and 0.83 (95%CI: 0.79˜0.86) on a per-vessel basis, respectively. The sensitivity, specificity and accuracy for intermediate lesions using cFFRML were 0.84, 0.92, and 0.89. No significant difference was found among different algorithms of CT-FFR (P < 0.001).

CONSLUSION: This multicenter study with meta-analysis showed that CT-FFR had a high diagnostic accuracy in determining ischemia-specific lesions and intermediate lesions. There was no significant difference when comparing the combined diagnostic performance of different algorithms of CT-FFR with invasive FFR as the reference standard.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Tang CX, Wang YN, Zhou F, et al. Diagnostic performance of fractional flow reserve derived from coronary CT angiography for detection of lesion-specific ischemia: A multi-center study and meta-analysis. Eur J Radiol. 2019. PMID: 31153580. doi:10.1016/j.ejrad.2019.04.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。