文献速递心血管CTMR

低剂量动态心肌灌注CT对急性心肌梗死患者微血管阻塞准确评估的价值

The Value of Low-Dose Dynamic Myocardial Perfusion CT for Accurate Evaluation of Microvascular Obstruction in Patients With Acute Myocardial Infarction.
PubMed 文献 · AJR Am J Roentgenol · 2019-06-05

前瞻性纳入27例急性心肌梗死后1周内成功再灌注患者,同日行心脏MRI与动态心肌灌注CT,以心脏MRI为标准评估AMI与MVO。结果显示MBF在识别AMI与MVO方面AUC最高(0.941和0.996),诊断MVO准确率99.2%,优于其他定量参数和LIE,且MBF估测的AMI与MVO面积与LGE相关性良好。

要点

  • MBF识别AMI(伴或不伴MVO)的AUC分别为0.941和0.996,均P<0.001。
  • MBF诊断MVO准确率99.2%,优于其他定量参数和LIE。
  • MVO节段MBF为23.08±7.95 mL/min/100 mL,显著低于无MVO节段44.60±14.97及参考节段75.07±7.34。

核心结论

  • 动态心肌灌注CT衍生的MBF诊断AMI和MVO准确,优于其他定量参数和LIE,且可准确估测AMI与MVO面积。

研究设计与样本

  • 前瞻性研究,纳入2018年1月1日至2018年5月31日间AMI后1周内成功再灌注治疗的患者27例、442个血管节段,同日行心脏MRI和动态心肌灌注CT,以心脏MRI为参考标准。

关键影像表现/征象

  • MVO节段MBF为23.08±7.95 mL/min/100 mL,低于无MVO节段44.60±14.97 mL/min/100 mL及参考节段75.07±7.34 mL/min/100 mL(P<0.001);MBF估测的AMI面积与MVO面积和LGE相关性良好(r=0.95和0.99,P<0.001)。

诊断标准与关键数值

  • 以LGE为参考,MBF识别AMI(伴或不伴MVO)的AUC分别为0.941和0.996(P<0.001);MBF诊断MVO准确率99.2%。动态心肌灌注CT平均辐射剂量3.3±1.1 mSv,LIE为2.0±0.6 mSv。

临床应用与阅片要点

  • 阅片时可利用动态心肌灌注CT定量MBF参数辅助识别AMI及MVO,并以MBF估测AMI与MVO面积。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study was to investigate the diagnostic performance of quantitative parameters generated from dynamic myocardial perfusion CT for assessment of acute myocardial infarction (AMI) and microvascular obstruction (MVO) using cardiac MRI as a reference standard. SUBJECTS AND METHODS. Patients who underwent successful reperfusion treatment within 1 week after AMI between January 1, 2018, and May 31, 2018, were prospectively enrolled. All patients were referred for cardiac MRI and dynamic myocardial perfusion CT on the same day. Various quantitative parameters and late iodine enhancement (LIE) were analyzed for the evaluation of AMI and MVO using cardiac MRI findings as a reference standard. RESULTS. Twenty-seven patients with 442 vascular segments were ultimately included in the analysis. The mean radiation doses ± SD for dynamic myocardial perfusion CT and LIE were 3.3 ± 1.1 mSv and 2.0 ± 0.6 mSv, respectively. Myocardial blood flow (MBF) was significantly lower in segments with MVO than in those without MVO and in reference segments (23.08 ± 7.95 mL/min/100 mL vs 44.60 ± 14.97 mL/min/100 mL and 75.07 ± 7.34 mL/min/100 mL; p < 0.001). According to ROC curve analysis, MBF had the largest AUC of all parameters for identifying AMI with and without MVO as determined by late gadolinium enhancement (LGE) (AUC = 0.941 and 0.996; p < 0.001). The diagnostic accuracy of MBF-based assessment for identifying MVO was 99.2%, which outperformed other quantitative parameters and LIE. We found good correlation between the AMI area and MVO area estimated by MBF and LGE (r = 0.95 and 0.99; p < 0.001). CONCLUSION. MBF derived from dynamic myocardial perfusion CT is accurate and outperforms other quantitative parameters and LIE in diagnosis of AMI and MVO. Area of AMI and MVO can also be accurately estimated using MBF.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Yu M, Chen X, Dai X, et al. The Value of Low-Dose Dynamic Myocardial Perfusion CT for Accurate Evaluation of Microvascular Obstruction in Patients With Acute Myocardial Infarction. AJR Am J Roentgenol. 2019. PMID: 31166762. doi:10.2214/AJR.19.21305

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。