舌下硝酸甘油剂量对FFRCT评估及冠状动脉管腔体积与心肌质量比值的影响
回顾性分析35例先后接受0.4 mg与0.8 mg舌下硝酸甘油冠状动脉CT血管成像的患者,比较FFRCT值、冠状动脉体积及体积/质量比。0.8 mg硝酸甘油使冠状动脉体积显著增加(2639 mm³ vs 2844.8 mm³,P=0.009),但FFRCT值与体积/质量比无显著变化。
要点
- 0.8 mg较0.4 mg舌下硝酸甘油使FFRCT分析所得的冠状动脉体积显著增加。
- 不同硝酸甘油剂量下,左、右及回旋支的FFRCT最低值均无显著差异。
- 冠状动脉体积/心肌质量比值不随硝酸甘油剂量增加而改变。
核心结论
- 常规临床CCTA中使用0.8 mg较0.4 mg硝酸甘油可显著增加FFRCT分析所得的冠状动脉体积,但不改变FFRCT值或体积/质量比。
研究设计与样本
- 回顾性分析35例有两次不同舌下喷雾硝酸甘油剂量(0.4 mg与0.8 mg)CCTA的患者,排除45例,两次CCTA间隔3.9±1.6年,采用Wilcoxon符号秩检验比较差异。
临床应用与阅片要点
- FFRCT分析依赖硝酸甘油诱导最大充血,但不同剂量对FFRCT值及体积/质量比的影响在阅片报告中需结合剂量考量。
- 0.8 mg硝酸甘油虽增加冠状动脉体积,但FFRCT值保持稳定,提示FFRCT解读可能不受该剂量差异显著影响。
局限性
- 原文为回顾性分析。
- 原文结论指出需以更 contemporaneous 的方式、使用不同硝酸盐剂量及疾病严重程度进一步评估重复CCTA。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Fractional flow reserve computed tomography (FFRCT) depends upon nitroglycerin (NTG) inducing maximal hyperemia. However, the impact of NTG dosages on FFRCT analysis including coronary volume-to-mass ratio (V/M) is unknown.
METHODS: Eighty patients with repeat coronary CT angiograms (CCTAs) with different sublingual spray NTG doses (0.4 mg and 0.8 mg) were retrospectively analyzed with 45 patients excluded. Patient and scan demographics, post-stenosis and nadir FFRCT values, coronary volume, and coronary volume-to-mass ratio (V/M) were compared at initial CCTA (0.4 mg NTG) and follow-up CCTA (0.8 mg NTG). Differences were compared by Wilcoxon signed-rank test.
RESULTS: Thirty-five patients were included (time between CCTAs, 3.9 ± 1.6 years). Segment involvement score was 2.4 ± 3.3 and 2.8 ± 3.4 at initial and repeat CCTA (0.4 and 0.8 mg NTG), respectively (p = 0.004). There was similar image quality (4.1 ± 0.7 vs 4.1 ± 0.8; p = 0.51). Nadir FFRCT values did not differ in the left (0.4 mg, 0.80 ± 0.08 vs 0.8 mg, 0.80 ± 0.03; p = 0.66), right (0.4 mg, 0.90 ± 0.04 vs 0.8 mg, 0.90 ± 0.06; p = 0.25), or circumflex coronaries (0.4 mg, 0.87 ± 0.06 vs 0.8 mg, 0.88 ± 0.06; p = 0.34). Post-stenosis FFRCT values did not differ (p = 0.65). Coronary volume increased with 0.8 mg of NTG (2639 ± 753 mm3 vs 2844.8 ± 827 mm3; p = 0.009) but V/M ratio did not (p = 0.20).
CONCLUSIONS: Use of 0.8 mg versus 0.4 mg of NTG in routine clinical CCTAs significantly increased coronary volume determined from FFRCT analysis but did not alter FFRCT or V/M. Further evaluation of repeat CCTAs in a more contemporaneous fashion using varied nitrate doses and disease severity is needed.
KEY POINTS: • Fractional flow reserve from computed tomography (FFRCT) is a noninvasive method for evaluating the coronary arteries and relies on nitroglycerin (NTG) to induce coronary vasodilation, but the impact of different NTG dosages is unknown. • Retrospective analysis evaluated use of different NTG doses on FFRCT. • Increased NTG dose increased coronary luminal volume on FFRCTanalysis, but did not change FFRCTvalues.
引用
- Holmes KR, Fonte TA, Weir-McCall J, et al. Impact of sublingual nitroglycerin dosage on FFRCT assessment and coronary luminal volume-to-myocardial mass ratio. Eur Radiol. 2019. PMID: 31227880. doi:10.1007/s00330-019-06293-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。