薄层CT上区分5-10mm磨玻璃结节为浸润性肺腺癌的衰减与形态学特征
回顾性分析288例患者313个手术确诊的5-10mm磨玻璃结节(GGN)的薄层CT特征,比较原位腺癌/微浸润腺癌(AIS-MIA组247个)与浸润性腺癌(IAC组66个)。IAC组病灶更大、衰减值更高、混合型GGN及分叶、毛刺、胸膜凹陷、气泡样外观更常见,肿瘤-肺界面清晰者更少。 logistic模型AUC为0.847(敏感度80.3%,特异度81.0%),显著高于单独使用大小或衰减值;GGN大于8.12mm且衰减值大于-449.52 HU更可能为IAC。
要点
- 5-10mm GGN中,IAC组较AIS-MIA组病灶更大、衰减值更高(均p<0.001)。
- IAC组混合型GGN、气泡样外观、毛刺、胸膜凹陷更常见,肿瘤-肺界面清晰者更少(均p<0.05)。
- logistic模型AUC 0.847(敏感度80.3%,特异度81.0%),显著高于单用大小或衰减值(均p<0.01)。
核心结论
- 薄层CT影像特征有助于鉴别5-10mm GGN为IAC还是AIS或MIA;GGN大于8.12mm且衰减值大于-449.52 HU更可能为IAC。
研究设计与样本
- 回顾性研究,纳入288例患者共313个手术确诊的GGN,采用薄层CT评估特征并建立logistic回归模型,以ROC曲线比较模型与病灶大小、衰减值的AUC。
关键影像表现/征象
- IAC组较AIS-MIA组病灶尺寸更大、衰减值更高(均p<0.001)。
- IAC组混合型GGN、气泡样外观、毛刺、胸膜凹陷及不同位置的出现频率更高(均p<0.05)。
- IAC组肿瘤-肺界面清晰的出现频率更低(p<0.05)。
诊断标准与关键数值
- logistic模型纳入大小(p<0.001;OR 1.872)、衰减值(p<0.001;OR 1.009)、肿瘤-肺界面(p=0.001;OR 0.242)、气泡样外观(p<0.05;OR 2.205)及结节类型。
- logistic模型AUC为0.847,敏感度80.3%,特异度81.0%。
- GGN大于8.12mm且衰减值大于-449.52 HU更可能为IAC。
临床应用与阅片要点
- 阅片5-10mm GGN时,应综合评估大小、衰减值、结节类型、肿瘤-肺界面、气泡样外观、毛刺及胸膜凹陷等特征。
- 对于大于8.12mm且衰减值大于-449.52 HU的GGN,需考虑IAC可能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study is to comprehensively investigate the role of multiple features seen on thin-section CT (TSCT) in the differential diagnosis of ground-glass nodules (GGNs) measuring 5-10 mm in diameter as invasive adenocarcinoma (IAC). MATERIALS AND METHODS. The TSCT features of 313 surgically diagnosed GGNs from 288 patients were retrospectively reviewed. A logistic regression model was applied, and the AUC values for the model and the size and attenuation of the lesions were compared using ROC curve analysis. RESULTS. A total of 247 lung adenocarcinomas in situ (AISs) and minimally invasive adenocarcinomas (MIAs) (hereafter referred to as the AIS-MIA group) and 66 invasive adenocarcinomas (IACs) were identified. Compared with the AIS-MIA group, the IAC groups were significantly larger in size and had higher attenuation values, a higher frequency of mixed GGNs (all p < 0.001), bubblelike appearance, spiculation, pleural indentation, different locations, and a lower frequency of clear tumor-lung interface (all p < 0.05). The logistic model included size and attenuation (both p < 0.001; odds ratio [OR], 1.872 and 1.009, respectively) as well as tumor-lung interface (p = 0.001; OR, 0.242), bubblelike appearance (p < 0.05; OR, 2.205), and type of nodule. The AUC value for the logistic model was 0.847 (sensitivity, 80.3%; specificity, 81.0%) and was significantly higher than that for size or attenuation (both p < 0.01). CONCLUSION. Radiologic features could help in the differential diagnosis of a GGN that was 5-10 mm in diameter as IAC versus AIS or MIA. GGNs larger than 8.12 mm and with attenuation greater than -449.52 HU were more likely to be IAC.
引用
- Zhan Y, Peng X, Shan F, et al. Attenuation and Morphologic Characteristics Distinguishing a Ground-Glass Nodule Measuring 5-10 mm in Diameter as Invasive Lung Adenocarcinoma on Thin-Slice CT. AJR Am J Roentgenol. 2019. PMID: 31216199. doi:10.2214/AJR.18.21008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。