文献速递胸部CT

基于深度学习的CT重建核图像转换提高肺结节或肿块放射组学特征的可重复性

Deep Learning-based Image Conversion of CT Reconstruction Kernels Improves Radiomics Reproducibility for Pulmonary Nodules or Masses.
PubMed 文献 · Radiology · 2019-06-18

该回顾性分析纳入104例肺结节或肿块患者,评估不同重建核(B30f与B50f)对702个放射组学特征的影响,并探讨卷积神经网络图像转换能否提高特征可重复性。结果显示不同核间仅15.2%特征可靠,经转换后可重复特征比例提高至57.4%。

要点

  • 不同重建核间仅15.2%放射组学特征可重复(CCC≥0.85),纹理与小波特征受影响最明显。
  • 卷积神经网络图像转换后,可重复特征比例由15.2%提升至57.4%。
  • 同一重建核下两位阅片者间CCC为0.92,84.3%特征可重复。

核心结论

  • 卷积神经网络图像转换有效降低了两种重建核的影响,可能提高肺结节或肿块放射组学特征的可重复性。

研究设计与样本

  • 回顾性分析,纳入104例患者(女54例、男50例,平均年龄63.2岁±10.5),2017年4月至6月使用单台CT扫描仪行非增强和增强胸部轴位CT,采用软组织核B30f和锐利核B50f重建。

诊断标准与关键数值

  • 共提取702个放射组学特征(肿瘤强度、纹理及小波特征);同一核两位阅片者间CCC为0.92,592/702(84.3%)特征可重复(CCC≥0.85);不同核间CCC为0.38,仅107/702(15.2%)特征可靠;纹理特征CCC由0.88降至0.61,小波特征由0.92降至0.35;图像转换后CCC提高至0.84,403/702(57.4%)特征可重复,纹理特征CCC为0.85,小波特征CCC为0.84。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Intratumor heterogeneity in lung cancer may influence outcomes. CT radiomics seeks to assess tumor features to provide detailed imaging features. However, CT radiomic features vary according to the reconstruction kernel used for image generation. Purpose To investigate the effect of different reconstruction kernels on radiomic features and assess whether image conversion using a convolutional neural network (CNN) could improve reproducibility of radiomic features between different kernels. Materials and Methods In this retrospective analysis, patients underwent non-contrast material-enhanced and contrast material-enhanced axial chest CT with soft kernel (B30f) and sharp kernel (B50f) reconstruction using a single CT scanner from April to June 2017. To convert different kernels without sinogram, the CNN model was developed using residual learning and an end-to-end way. Kernel-converted images were generated, from B30f to B50f and from B50f to B30f. Pulmonary nodules or masses were semiautomatically segmented and 702 radiomic features (tumor intensity, texture, and wavelet features) were extracted. Measurement variability in radiomic features was evaluated using the concordance correlation coefficient (CCC). Results A total of 104 patients were studied, including 54 women and 50 men, with pulmonary nodules or masses (mean age, 63.2 years ± 10.5). The CCC between two readers using the same kernel was 0.92, and 592 of 702 (84.3%) of the radiomic features were reproducible (CCC ≥ 0.85); using different kernels, the CCC was 0.38 and only 107 of 702 (15.2%) of the radiomic features were reliable. Texture features and wavelet features were predominantly affected by reconstruction kernel (CCC, from 0.88 to 0.61 for texture features and from 0.92 to 0.35 for wavelet features). After applying image conversion, CCC improved to 0.84 and 403 of 702 (57.4%) radiomic features were reproducible (CCC, 0.85 for texture features and 0.84 for wavelet features). Conclusion Chest CT image conversion using a convolutional neural network effectively reduced the effect of two different reconstruction kernels and may improve the reproducibility of radiomic features in pulmonary nodules or masses. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Park in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Choe J, Lee SM, Do KH, et al. Deep Learning-based Image Conversion of CT Reconstruction Kernels Improves Radiomics Reproducibility for Pulmonary Nodules or Masses. Radiology. 2019. PMID: 31210613. doi:10.1148/radiol.2019181960

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。