基于深度卷积编码器-解码器仅用发射数据直接衰减校正脑PET图像(Deep-DAC)
研究纳入129例患者脑PET图像,用卷积编码器-解码器网络将未衰减校正(NAC)图像直接映射为实测衰减校正(MAC)PET图像。外部验证集PSNR为39.2±3.65、SSIM为0.989±0.006;83个脑区中SUVmean的RE仅3个区显著,SUVmax有17个区显著,Haralick homogeneity有20个区显著。作者认为该直接衰减校正技术对脑PET有前景。
要点
- 仅用发射数据即可直接生成衰减校正PET图像,无需解剖信息。
- 外部验证集图像质量指标PSNR 39.2±3.65、SSIM 0.989±0.006。
- SUVmean的RE在83个脑区中仅3个区显著,SUVmax有17个区显著。
核心结论
- 使用深度卷积编码器-解码器网络直接对PET图像进行衰减校正是脑PET成像的一种有前景的技术,在PET/MRI和专用脑PET扫描仪中具有应用潜力。
研究设计与样本
- 研究论文;纳入129例患者的脑PET图像,网络将未衰减校正(NAC)图像映射为像素级连续值的实测衰减校正(MAC)PET图像,用多种指标评估图像质量,并以Hammersmith图谱(n30r83)划分的83个脑区、19个影像组学特征评估定量可靠性。
关键影像表现/征象
- 外部验证集峰值信噪比(PSNR)为39.2±3.65,结构相似性指数(SSIM)为0.989±0.006。
- 全部脑区SUVmean的相对误差(RE)为-0.10±2.14,83个脑区中仅3个区差异显著,该区域平均RE为0.02(范围-0.83至1.18)。
- 全部脑区SUVmax的平均RE为-3.87±2.84,17个脑区与MAC图像相比差异显著,平均RE为-3.99±2.11(范围-8.46至0.76)。
- 基于Haralick的影像组学特征中,homogeneity有20个脑区差异显著,为差异显著区数最多的特征,平均RE为7.22±2.99。
诊断标准与关键数值
- 以实测衰减校正(MAC)PET图像为参考,采用像素级相对误差(RE;%)评估影像组学特征值的测量可靠性。
- 外部验证集图像质量以PSNR 39.2±3.65和SSIM 0.989±0.006评估。
临床应用与阅片要点
- 该方法仅用发射数据即可实现PET衰减校正,作者认为在PET/MRI和专用脑PET扫描仪中有应用潜力。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To obtain attenuation-corrected PET images directly from non-attenuation-corrected images using a convolutional encoder-decoder network.
METHODS: Brain PET images from 129 patients were evaluated. The network was designed to map non-attenuation-corrected (NAC) images to pixel-wise continuously valued measured attenuation-corrected (MAC) PET images via an encoder-decoder architecture. Image quality was evaluated using various evaluation metrics. Image quantification was assessed for 19 radiomic features in 83 brain regions as delineated using the Hammersmith atlas (n30r83). Reliability of measurements was determined using pixel-wise relative errors (RE; %) for radiomic feature values in reference MAC PET images.
RESULTS: Peak signal-to-noise ratio (PSNR) and structural similarity index metric (SSIM) values were 39.2 ± 3.65 and 0.989 ± 0.006 for the external validation set, respectively. RE (%) of SUVmean was - 0.10 ± 2.14 for all regions, and only 3 of 83 regions depicted significant differences. However, the mean RE (%) of this region was 0.02 (range, - 0.83 to 1.18). SUVmax had mean RE (%) of - 3.87 ± 2.84 for all brain regions, and 17 regions in the brain depicted significant differences with respect to MAC images with a mean RE of - 3.99 ± 2.11 (range, - 8.46 to 0.76). Homogeneity amongst Haralick-based radiomic features had the highest number (20) of regions with significant differences with a mean RE (%) of 7.22 ± 2.99.
CONCLUSIONS: Direct AC of PET images using deep convolutional encoder-decoder networks is a promising technique for brain PET images. The proposed deep learning method shows significant potential for emission-based AC in PET images with applications in PET/MRI and dedicated brain PET scanners.
KEY POINTS: • We demonstrate direct emission-based attenuation correction of PET images without using anatomical information. • We performed radiomics analysis of 83 brain regions to show robustness of direct attenuation correction of PET images. • Deep learning methods have significant promise for emission-based attenuation correction in PET images with potential applications in PET/MRI and dedicated brain PET scanners.
引用
- Shiri I, Ghafarian P, Geramifar P, et al. Direct attenuation correction of brain PET images using only emission data via a deep convolutional encoder-decoder (Deep-DAC). Eur Radiol. 2019. PMID: 31227879. doi:10.1007/s00330-019-06229-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。