经双腔球囊递送低剖面支架行颅内动脉瘤栓塞的「联合重塑技术」的安全性与有效性:多中心经验
多中心研究分析84例患者86个颅内动脉瘤,经双腔球囊递送低剖面支架行「联合重塑技术」栓塞,技术并发症率11.6%,随访71例平均7个月,完全及近完全闭塞率90.1%。作者认为该技术技术上可行、安全、有效,可使术者避免额外操作。
要点
- 经双腔球囊递送低剖面支架的联合重塑技术可用于颅内动脉瘤栓塞。
- 术中技术并发症率11.6%,轻微临床事件2.4%,主要事件1.2%。
- 随访71例平均7个月,完全及近完全闭塞率90.1%,残留动脉瘤9.9%。
核心结论
- 经双腔球囊递送低剖面支架的「联合重塑技术」治疗颅内动脉瘤技术上可行、安全、有效。
- 该技术可使术者避免额外操作。
研究设计与样本
- 多中心研究,纳入84例患者(55例女性,年龄范围20-81岁)共86个颅内动脉瘤。
- 分析临床、操作及血管造影数据。
- 植入93枚装置:LVIS jr 63枚、LEO Baby 15枚、ACCLINO Flex 14枚、Neuroform Atlas 1枚,均经双腔球囊(Scepter C或XC、Eclipse 2 L)递送。
关键影像表现/征象
- 动脉瘤最大径2-26 mm,平均7.5 mm。
- 动脉瘤部位:大脑前交通动脉31个、大脑中动脉36个、床突上段颈内动脉4个、颈动脉分叉2个、基底动脉7个、大脑后动脉3个、小脑后下动脉2个、椎动脉1个。
- 动脉瘤状态:未破裂62个、再通15个、急性破裂9个。
诊断标准与关键数值
- 随访71例,平均随访7个月,完全及近完全闭塞率90.1%,残留动脉瘤9.9%。
- 术中技术并发症率11.6%,轻微临床事件2.4%(2例),主要事件1.2%(1例)。
临床应用与阅片要点
- 原文未据此给出具体阅片或报告建议。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Since appearance of the balloon-remodeling technique and stent-assisted coiling, complex aneurysms have been treated successfully by endovascular means worldwide. Although these two techniques have been widely proven, the combination of both traditionally made the procedures more complicated technically. The aim of our study was to determine the technical success, safety, and efficacy of the low-profile stents delivered through double lumen balloons.
METHODS: Clinical, procedural, and angiographic data were analyzed.
RESULTS: Eighty-four patients (55 women; age range 20-81 years) harboring 86 aneurysms were included in this study. Aneurysm maximal diameter ranged from 2 to 26 mm, with mean 7.5 mm. There were 62 unruptured, 15 recanalized, and 9 acutely ruptured aneurysms. Aneurysm locations were ACoA (31), MCA (36), supraclinoid ICA (4), carotid bifurcation (2), basilar (7), PCA (3), PICA (2), and VA (1). Ninety-three devices were implanted (63 LVIS jr, 15 LEO Baby, 14 ACCLINO Flex and 1 Neuroform Atlas) through the double lumen balloons (Scepter C or XC and Eclipse 2 L). We found 2 minor clinical events (2.4%) and 1 major event (1.2%). Total intra-procedural technical complication rate was 11.6%. Follow-up was available for 71 patients with an average follow-up of 7 months. Complete and near complete occlusion was 90.1%. Residual aneurysms were seen in 9.9%.
CONCLUSION: The "combined remodeling technique" with low-profile stents delivered through double-lumen balloons is technically feasible, safe, and effective for the treatment of intracranial aneurysms. This technique allows the operator to avoid extra maneuvers.
引用
- Martínez-Galdámez M, Orlov K, Kadziolka K, et al. Safety and efficacy of intracranial aneurysm embolization using the "combined remodeling technique": low-profile stents delivered through double lumen balloons: a multicenter experience. Neuroradiology. 2019. PMID: 31203413. doi:10.1007/s00234-019-02240-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。