颅骨缺损对CTA确认脑死亡作用的影响
本研究评估颅骨缺损及图像判读标准对CTA确认脑死亡诊断效能的影响。连续纳入临床诊断脑死亡患者行CTA,对照组为同期急性缺血性卒中患者。Frampas标准下完整颅骨、开颅术、去骨瓣减压术的敏感度分别为95.5%、87.5%、60%;采用改良Frampas标准后分别升至100%、93.8%、80%。
要点
- 颅骨缺损尤其是去骨瓣减压术可降低CTA确认脑死亡的敏感度。
- 改良Frampas标准可提高CTA敏感度,颅骨缺损患者尤为明显。
- 完整颅骨患者中CTA诊断准确度高且观察者间无分歧。
核心结论
- CTA在完整颅骨患者中确认脑死亡具有高诊断准确度和可重复性。
- 改良Frampas标准提高了CTA的敏感度,尤其在颅骨缺损患者中。
- 合并颅骨缺损尤其是去骨瓣减压术可降低CTA确认脑死亡的敏感度。
研究设计与样本
- 连续纳入临床诊断脑死亡患者行CTA作为病例组,对照组为同期急性缺血性卒中患者。
- CTA确认脑死亡的标准为M4分支和大脑内静脉无强化,并评估是否存在「淤滞充盈」。
- 病例按颅骨完整、开颅术、去骨瓣减压术分层,由三名神经放射科医师独立评估所有检查。
关键影像表现/征象
- 按Frampas标准,病例组中假阴性诊断脑死亡占15.6%,其中71.4%与淤滞充盈相关(P < .001)。
- 按改良Frampas标准,假阴性诊断脑死亡见于6.2%的患者,且无淤滞充盈。
诊断标准与关键数值
- Frampas标准确认脑死亡的敏感度:颅骨完整95.5%,开颅术87.5%,去骨瓣减压术60%。
- 改良Frampas标准确认脑死亡的敏感度:颅骨完整100%,开颅术93.8%,去骨瓣减压术80%。
- CTA在对照组中特异度为100%。
临床应用与阅片要点
- 阅片评估CTA确认脑死亡时需注意患者是否存在颅骨缺损,尤其是去骨瓣减压术后。
- 判读时需关注淤滞充盈,其与Frampas标准下的假阴性诊断相关。
- 对颅骨缺损患者采用改良Frampas标准可提高确认脑死亡的敏感度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Intracranial pressure modifications caused by a skull defect, such as craniectomy or craniotomy, may change the hemodynamics and decrease the accuracy of CTA to confirm brain death. This study aimed to evaluate the impact of a skull defect and the interpretation criteria of images on this diagnostic test.
MATERIALS AND METHODS: A series of consecutive patients with a clinical diagnosis of brain death underwent CTA (case group), while the control group comprised patients with acute ischemic stroke in the same period. CTA criteria adopted to confirm brain death were the absence of opacification of the M4 branches and internal cerebral veins. The evaluation also included the presence of "stasis filling." Cases were stratified as intact skull, craniotomy, and craniectomy. Three neuroradiologists evaluated all examinations independently.
RESULTS: In the case group, according to the Frampas criteria, the sensitivity of CTA to confirm brain death was 95.5% in patients with intact skull, 87.5% with craniotomy, and 60% with craniectomy. False-negative diagnoses of brain death were 15.6%, related to stasis filling in 71.4% (P < .001). However, according to the "modified Frampas criteria," the sensitivity of CTA to confirm brain death was 100% in patients with intact skull, 93.8% with craniotomy, and 80% with craniectomy. False-negative diagnoses of brain death were found in 6.2% of patients, and there was no stasis filling. CTA showed 100% specificity in the control group. There were no disagreements among observers.
CONCLUSIONS: CTA had a high diagnostic accuracy and reproducibility to confirm brain death in patients with an intact skull. The modified Frampas criteria increased the sensitivity of CTA, particularly in patients with a skull defect. A concurrent skull defect, especially craniectomy, can decrease the sensitivity of CTA to confirm brain death.
引用
- Nunes DM, Maia ACM, Boni RC, et al. Impact of Skull Defects on the Role of CTA for Brain Death Confirmation. AJNR Am J Neuroradiol. 2019. PMID: 31196858. doi:10.3174/ajnr.A6100
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。