脑SPECT与灌注MRI:能否为肿瘤病灶及其分级提供互补信息?
研究纳入36例临床疑似脑肿瘤患者,均经组织病理学证实,评估99mTc-替曲膦脑SPECT与动态磁敏感对比灌注MRI在胶质瘤分级中的相对与联合效用。T-index截断值6.35鉴别高级别与低级别胶质瘤的敏感度为82%、特异度为71%,rCBV比值截断值1.80的敏感度为91%、特异度为100%;两种技术任一项阳性时特异度相近、敏感度略增高。
要点
- rCBV比值截断值1.80鉴别高级别与低级别胶质瘤:敏感度91%、特异度100%。
- T-index截断值6.35:敏感度82%、特异度71%,特异度低于rCBV比值。
- 两种技术任一项阳性时特异度相近、敏感度略增高。
核心结论
- 99mTc-替曲膦SPECT与DSC灌注MRI可能提供互补的肿瘤分级指标,并对高危肿瘤具有独立诊断价值。
研究设计与样本
- 研究纳入36例临床疑似脑肿瘤患者,均经组织病理学证实为脑肿瘤。
- 全部患者接受99mTc-替曲膦脑SPECT与DSC灌注MRI检查,两种技术均采用视觉与半定量分析(分别得出替曲膦指数T-index与相对脑血容量rCBV比值)。
- 以组织病理学为参考标准确认肿瘤恶性程度,通过ROC分析获取各指标鉴别低级别与高级别胶质瘤的最佳截断值。
关键影像表现/征象
- 99mTc-替曲膦SPECT在31/36例患者中显示示踪剂摄取异常升高,MRI在所有患者中均检出脑肿瘤。
诊断标准与关键数值
- T-index截断值6.35鉴别高级别与低级别胶质瘤:敏感度82%、特异度71%。
- rCBV比值截断值1.80鉴别高级别与低级别胶质瘤:敏感度91%、特异度100%。
- 要求两种技术任一项阳性以判定高级别胶质瘤时,特异度相近、敏感度略增高。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the relative and combined utility of 99mTc-tetrofosmin (99mTc-TF) brain single-photon-emission computed tomography (SPECT) and dynamic susceptibility contrast (DSC) perfusion magnetic resonance imaging (MRI) in grading brain gliomas.
MATERIALS AND METHODS: Thirty-six patients with clinically suspected brain tumours were assessed by 99mTc-TF SPECT and DSC-MRI. Brain tumour malignancy was confirmed in all patients at histopathology. On both techniques brain lesions were evaluated via visual and semi-quantitative analysis methods (deriving tetrofosmin index [T-index] and relative cerebral blood volume [rCBV] ratios, respectively).
RESULTS: 99mTc-TF SPECT showed abnormally elevated tracer uptake in 31/36 patients whereas MRI detected the brain tumour in all patients. Optimal cut-off values of each index for discriminating between low- and high-grade gliomas were obtained through receiver operating characteristic (ROC) analyses. A T-index cut-off of 6.35 ensured 82% sensitivity and 71% specificity for discriminating between high- and low-grade gliomas, whereas a relative rCBV ratio cut-off of 1.80 achieved 91% sensitivity and 100% specificity. Requiring a positive result on either technique to characterise a high-grade glioma was associated with similar specificity and slightly increased sensitivity.
CONCLUSION: Both imaging techniques, 99mTF SPECT and DSC MRI, may provide complementary indices of tumour grade and have an independent diagnostic value for high-risk tumours.
引用
- Daboudi M, Papadaki E, Vakis A, et al. Brain SPECT and perfusion MRI: do they provide complementary information about the tumour lesion and its grading? Clin Radiol. 2019. PMID: 31164195. doi:10.1016/j.crad.2019.03.025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。