文献速递神经MR

多发性硬化3T MRI不同平面内分辨率下合成MRI的脑组织与髓鞘体积分析

Brain tissue and myelin volumetric analysis in multiple sclerosis at 3T MRI with various in-plane resolutions using synthetic MRI.
PubMed 文献 · Neuroradiology · 2019-06-18

研究纳入19例多发性硬化患者与10名年龄性别匹配健康对照,在3T MRI上以0.8、1.8、3.6 mm平面内分辨率行合成MRI,比较脑组织与髓鞘体积。0.8与1.8 mm分辨率间多数体积无显著差异,3.6 mm与更细分辨率间多数脑组织体积差异显著;0.8与1.8 mm分辨率下归一化白质体积、髓鞘体积及脑实质体积在两组间差异显著。结论认为平面内分辨率低至1.8 mm、采集时间<3分钟的合成MRI可用于多发性硬化评估。

要点

  • 0.8与1.8 mm平面内分辨率间多数脑组织体积无显著差异,采集时间分别为5分8秒与2分52秒。
  • 3.6 mm与0.8或1.8 mm分辨率相比多数脑组织体积差异显著,采集时间2分1秒。
  • 0.8与1.8 mm分辨率下归一化白质体积、髓鞘体积及脑实质体积在健康对照与多发性硬化患者间差异显著。

核心结论

  • 合成MRI脑组织与髓鞘体积测量在平面内分辨率低至1.8 mm、采集时间<3分钟时可能有助于多发性硬化评估。

研究设计与样本

  • 研究扫描19例多发性硬化患者与10名年龄性别匹配健康对照,使用3T MR扫描仪,平面内分辨率分别为0.8、1.8、3.6 mm,采集时间分别为5分8秒、2分52秒、2分1秒。

关键影像表现/征象

  • 比较不同平面内分辨率下白质、灰质、脑脊液、髓鞘及非白质/灰质/脑脊液体积、脑实质体积与颅内体积。
  • 0.8与1.8 mm分辨率间测量体积除健康对照的非白质/灰质/脑脊液与脑脊液及多发性硬化患者的非白质/灰质/脑脊液外无显著差异。
  • 3.6 mm与0.8或1.8 mm分辨率相比,健康对照与多发性硬化患者多数脑组织体积差异显著。

诊断标准与关键数值

  • 经颅内体积归一化后,0.8与1.8 mm平面内分辨率下归一化白质体积、髓鞘体积及脑实质体积在健康对照与多发性硬化患者间差异显著。

临床应用与阅片要点

  • 合成MRI可在平面内分辨率低至1.8 mm、采集时间<3分钟时获取脑组织与髓鞘体积信息。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Synthetic MRI (SyMRI) enables automatic brain tissue and myelin volumetry based on the quantification of R1 and R2 relaxation rates and proton density. This study aimed to determine the validity of SyMRI brain tissue and myelin volumetry using various in-plane resolutions at 3T in patients with multiple sclerosis (MS).

METHODS: We scanned 19 MS patients and 10 healthy age- and gender-matched controls using a 3T MR scanner with in-plane resolutions of 0.8, 1.8, and 3.6 mm. The acquisition times were 5 min 8 s, 2 min 52 s, and 2 min 1 s, respectively. White matter (WM), gray matter (GM), cerebrospinal fluid (CSF), and myelin and non-WM/GM/CSF (NoN) volumes; brain parenchymal volume (BPV); and intracranial volume (ICV) were compared between different in-plane resolutions. These parameters were also compared between both groups, after ICV normalization.

RESULTS: No significant differences in measured volumes were noted between the 0.8 and 1.8 mm in-plane resolutions, except in NoN and CSF for healthy controls and NoN for MS patients. Meanwhile, significant volumetric differences were noted in most brain tissues when compared between the 3.6 and 0.8 or 1.8 mm resolution for both healthy controls and MS patients. The normalized WM volume, myelin volume, and BPV showed significant differences between controls and MS patients at in-plane resolutions of 0.8 and 1.8 mm.

CONCLUSIONS: SyMRI brain tissue and myelin volumetry with in-plane resolution as low as 1.8 mm can be useful in the evaluation of MS with a short acquisition time of < 3 min.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Saccenti L, Andica C, Hagiwara A, et al. Brain tissue and myelin volumetric analysis in multiple sclerosis at 3T MRI with various in-plane resolutions using synthetic MRI. Neuroradiology. 2019. PMID: 31209528. doi:10.1007/s00234-019-02241-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。