颅内囊状与梭形动脉瘤的壁强化在强度和范围上可能不同:一项采用7-T高分辨率黑血MRI的初步研究
本研究用7-T黑血MRI评估31例患者32个未破裂颅内动脉瘤(21个囊状、11个梭形)的壁强化模式与程度。梭形动脉瘤全部强化且均为2级,强化范围更广、信号强度更高(p<0.01),而两组大小相似(6.9±3.0 mm vs 8.0±2.9 mm,p=0.23)。囊状动脉瘤中较大者强化程度更高(Pearson r=0.64,p=0.002)。
要点
- 7-T黑血MRI可可靠显示颅内动脉瘤壁强化,梭形动脉瘤均呈均匀2级强化。
- 梭形动脉瘤壁强化范围更广、信号强度更高,提示血管壁病理可能不同。
- 囊状动脉瘤中,瘤体越大壁强化程度越高(Pearson r=0.64,p=0.002)。
核心结论
- 颅内梭形动脉瘤较囊状动脉瘤壁强化信号强度更高、覆盖范围更广,可能提示两者血管壁病理存在差异。
研究设计与样本
- 初步研究,纳入31例患者共32个未破裂颅内动脉瘤(21个囊状、11个梭形),采用7-T高分辨率黑血MRI评估动脉瘤壁强化,使用卡方检验比较两组强化模式与程度。
关键影像表现/征象
- 囊状动脉瘤中12/21(57%)出现壁强化,其中9个为局灶性强化(5个1级、4个2级),3个为均匀性强化(2个1级、1个2级)。
- 梭形动脉瘤中11/11(100%)出现壁强化,其中1个为局灶性强化、10个为均匀性强化,且全部为2级强化。
- 梭形动脉瘤壁强化范围更广、信号强度更高(p<0.01),而两组动脉瘤大小相似(6.9±3.0 mm vs 8.0±2.9 mm,p=0.23)。
- 囊状动脉瘤中,瘤体越大壁强化程度越高(Pearson r=0.64,p=0.002)。
诊断标准与关键数值
- 动脉瘤壁强化分为无强化(NWE)、局灶性强化(FWE)和均匀性强化(UWE)。
- 强化程度评分:0分为无强化;1分为动脉瘤壁信号强度低于垂体柄;2分为动脉瘤壁信号强度等于垂体柄。
临床应用与阅片要点
- 7-T黑血MRI可用于可靠评估颅内动脉瘤壁强化,阅片时需区分局灶性与均匀性强化并记录强化程度。
- 梭形动脉瘤多表现为均匀性2级强化,囊状动脉瘤强化模式较多样,报告时应结合形态学描述。
- 囊状动脉瘤较大者壁强化程度更高,阅片时需留意瘤体大小与强化程度的关系。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate and compare wall enhancement patterns in saccular and fusiform intracranial aneurysms using high-resolution black-blood MRI at 7 T.
METHODS: Thirty-one patients with 32 unruptured intracranial aneurysms (21 saccular and 11 fusiform) underwent 7-T black-blood MRI. Aneurysm wall enhancement (AWE) was categorized as follows: no wall enhancement (NWE), focal wall enhancement (FWE), and uniform wall enhancement (UWE). The degree of enhancement was scored as follows: 0 (no enhancement), 1 (signal intensity (SI) of the aneurysm wall less than that of the pituitary infundibulum), and 2 (equal to that of the pituitary infundibulum). The chi-squared test was used to compare the AWE pattern and degree between saccular and fusiform aneurysms.
RESULTS: In saccular aneurysms, 12/21 (57%) enhanced. Of these, 9 showed FWE (5 grade 1 and 4 grade 2), and 3 showed UWE (2 grade 1 and 1 grade 2). In fusiform aneurysms, 11/11 (100%) enhanced. Of these, 1 showed FWE and 10 showed UWE. All fusiform aneurysms had grade-2 enhancement. Fusiform aneurysms had more extensive and higher SI AWE than saccular aneurysms (p < 0.01) despite having a similar size (6.9 ± 3.0 mm vs. 8.0 ± 2.9, p = 0.23). For saccular aneurysm, larger aneurysm size was correlated with higher degree of enhancement with Pearson's r = 0.64 (p = 0.002).
CONCLUSION: Intracranial fusiform aneurysms had enhancement of higher SI and that covered a more extensive area than saccular aneurysms, which might indicate differences in vessel wall pathology.
KEY POINTS: • Intracranial aneurysm wall enhancement can be reliably characterized by 7-T black-blood MRI. • AWE in intracranial fusiform aneurysms presents over a larger surface area and with greater signal intensity as compared with that in saccular aneurysms, which might indicate differences in pathology. • Stronger signal intensity of AWE correlates with the aneurysm size in saccular aneurysms.
引用
- Liu X, Zhang Z, Zhu C, et al. Wall enhancement of intracranial saccular and fusiform aneurysms may differ in intensity and extension: a pilot study using 7-T high-resolution black-blood MRI. Eur Radiol. 2019. PMID: 31218429. doi:10.1007/s00330-019-06275-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。