文献速递神经外周血管MRCT

3D-TOF-MRA测定的血流分数与大脑中动脉狭窄患者脑灌注的相关性

Association of Fractional Flow on 3D-TOF-MRA with Cerebral Perfusion in Patients with MCA Stenosis.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-06-13

这项前瞻性研究连续纳入429例症状性颅内动脉狭窄患者,最终分析91例单侧大脑中动脉M1段狭窄(狭窄程度50%~99%)患者,比较3D-TOF-MRA测定的血流分数与脑CTP灌注结果。ROC曲线显示血流分数鉴别正常灌注与低灌注的阈值为0.90(敏感度70.1%,特异度69.6%),血流分数≤0.90与狭窄远端脑低灌注独立相关(校正OR=3.68,P=.027)。作者认为3D-TOF-MRA血流分数可能作为无创实用工具用于判断症状性大脑中动脉狭窄患者的脑低灌注。

要点

  • 3D-TOF-MRA血流分数≤0.90与狭窄远端脑低灌注独立相关(校正OR=3.68)。
  • 血流分数鉴别正常灌注与低灌注的阈值为0.90,敏感度70.1%、特异度69.6%。
  • 作者认为该指标可能作为无创实用工具判断症状性大脑中动脉狭窄的脑低灌注。

核心结论

  • 3D-TOF-MRA测定的血流分数可能作为无创实用工具,用于判断症状性大脑中动脉狭窄患者的脑低灌注。

研究设计与样本

  • 前瞻性研究,经机构审查委员会批准,2015年6月至2018年5月连续招募429例症状性颅内动脉狭窄患者,最终分析91例单侧大脑中动脉M1段狭窄且狭窄程度50%~99%的患者,均行常规脑MR成像、3D-TOF-MRA和脑CTP。

关键影像表现/征象

  • 通过比较狭窄远近端信号强度变化在3D-TOF-MRA上测定血流分数。
  • 血流分数≤0.90的患者与狭窄部位远端脑低灌注独立相关(校正OR=3.68;95%CI 1.63-11.62;P=.027)。

诊断标准与关键数值

  • 血流分数鉴别正常灌注与低灌注的ROC曲线阈值为0.90,敏感度70.1%(95%CI 55.9%-81.2%),特异度69.6%(95%CI 47.6%-84.1%)。

临床应用与阅片要点

  • 作者认为3D-TOF-MRA血流分数可能作为无创实用工具用于判断症状性大脑中动脉狭窄患者的脑低灌注。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Fractional flow measured on 3D-TOF-MRA was proposed to quantify cerebral hemodynamic changes in patients with artery stenosis. We investigated the association between fractional flow and cerebral perfusion changes in patients with symptomatic MCA stenosis.

MATERIALS AND METHODS: This prospective study was approved by the institutional review board, and all participants provided written informed consent. From June 2015 to May 2018, four hundred twenty-nine patients with symptomatic intracranial arterial stenosis were consecutively recruited and underwent conventional brain MR imaging, 3D-TOF-MRA, and brain CTP. A total of 91 patients with unilateral M1 segment stenosis of the MCA and a stenosis degree of 50%∼99% were included in the analysis. Fractional flow was measured by comparing distal and proximal signal intensity changes across the stenosis on 3D-TOF-MRA. The cutoff value for fractional flow for discriminating between normal perfusion and hypoperfusion was obtained from the receiver operating characteristic curve. Associations between fractional flow and hypoperfusion were assessed using univariate and multivariate analyses.

RESULTS: The receiver operating characteristic curve showed a significant fractional flow threshold value at 0.90 (sensitivity, 70.1%; 95% CI, 55.9%-81.2%; specificity, 69.6%; 95% CI, 47.6%-84.1%). Participants with a fractional flow of ≤0.90 were independently associated with cerebral hypoperfusion downstream from the stenosis site (adjusted OR, 3.68; 95% CI, 1.63-11.62; P = .027).

CONCLUSIONS: Fractional flow measured on 3D-TOF-MRA may serve as a noninvasive and practical tool for determining the cerebral hypoperfusion in patents with symptomatic MCA stenosis.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Ge X, Zhao H, Zhou Z, et al. Association of Fractional Flow on 3D-TOF-MRA with Cerebral Perfusion in Patients with MCA Stenosis. AJNR Am J Neuroradiol. 2019. PMID: 31196857. doi:10.3174/ajnr.A6095

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。