视乳头水肿:视神经乳头弥散加权成像研究
本研究对32例视乳头水肿患者及32例年龄性别匹配对照行脑MRI(含读出分段回波平面DWI),按改良Frisén量表临床分级,两位神经放射科医师独立评估视神经乳头高信号及ADC值。视神经乳头高信号与临床分级及组间比较均有显著相关,高信号敏感度87.5%、特异度97.1%和98.6%,平均ADC截断值敏感度96.83%、特异度95.31%。
要点
- 视神经乳头DWI高信号是视乳头水肿的高敏感(87.5%)、高特异(97.1%和98.6%)征象。
- 视神经乳头平均ADC截断值鉴别视乳头水肿与对照的敏感度96.83%、特异度95.31%。
- 视神经乳头高信号及平均ADC值与视乳头水肿临床分级显著相关。
核心结论
- 视神经乳头弥散参数与视乳头水肿临床分级显著相关,可能作为颅内压的替代标志物。
研究设计与样本
- 研究纳入32例视乳头水肿患者及32例年龄性别匹配对照,行脑MRI包括基于读出分段回波平面成像的DWI,以改良Frisén量表为临床分级参考,两位神经放射科医师独立评估。
关键影像表现/征象
- 视神经乳头DWI高信号与视乳头水肿临床分级显著相关。
- 视神经乳头平均ADC值与视乳头水肿临床分级显著相关。
- 视神经乳头高信号及平均ADC值在病例组与对照组间差异显著。
诊断标准与关键数值
- 视神经乳头高信号诊断视乳头水肿:观察者1特异度97.1%,观察者2特异度98.6%,两者敏感度均为87.5%。
- 视神经乳头平均ADC截断值鉴别病例与对照:敏感度96.83%,特异度95.31%。
临床应用与阅片要点
- 阅读脑MRI DWI时注意评估视神经乳头高信号,该征象对视乳头水肿敏感度和特异度均较高。
- 可测量视神经乳头ADC值辅助区分视乳头水肿与正常对照,原文报告的平均截断值敏感度96.83%、特异度95.31%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To establish the correlation between clinical grading of papilloedema and diffusion abnormalities of optic nerve head (ONH) on diffusion-weighted imaging (DWI).
MATERIALS AND METHODS: Brain magnetic resonance imaging (MRI), including readout segmented echo planar imaging-based DWI, was performed in 32 patients with papilloedema and the same number of age- and sex-matched controls. Clinical grading of papilloedema was done according to the modified Frisén scale. Two neuroradiologists independently evaluated the MRI for ONH hyperintensity and apparent diffusion coefficient (ADC) value of ONH. The comparison between papilloedema clinical grade and qualitative grade of ONH hyperintensity and its presence between cases and control groups were done using the Chi-square test and Fisher's exact test, respectively. The comparison between mean ADC value of ONH among different grades and between cases and controls were done using analysis of variance (ANOVA)-F-test and Student's t-test, respectively. Receiver operating characteristic (ROC) analysis was done to calculate a cut-off ADC value between the case and control groups.
RESULTS: Significant correlation between ONH hyperintensity and mean ADC value of ONH with clinical grades of papilloedema and between cases and control groups were found. ONH hyperintensity was found to be a highly sensitive (87.5% for both) and specific (specificity 97.1% and 98.6% for two observers) sign of papilloedema. A mean cut-off ONH ADC value was found to have high sensitivity (96.83%) and specificity (95.31%) to distinguish between the cases and controls.
CONCLUSIONS: Diffusion parameters of ONH have significant correlation with clinical grading of papilloedema and can serve as a surrogate marker for intracranial pressure.
引用
- N Ray, Vyas S, Khandelwal N, et al. Papilloedema: diffusion-weighted imaging of optic nerve head. Clin Radiol. 2019. PMID: 31202568. doi:10.1016/j.crad.2019.05.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。