2017 ACR TI-RADS指南与Kwak指南在儿童甲状腺结节诊断性能中的比较
该回顾性研究纳入75例在三级儿科医院接受甲状腺超声的儿童,由3名儿科放射科医师和1名儿科放射学研究员分别用Kwak-TI-RADS和ACR TI-RADS对超声表现评分。ACR TI-RADS的评分者间一致性显著优于Kwak-TI-RADS(P<0.001),但两者诊断性能无显著差异,AUROCC分别为0.72(95%CI 0.61-0.82)和0.74(95%CI 0.67-0.82)。两种指南对儿童甲状腺结节均提供中等程度的恶性风险分层,ACR TI-RADS一致性更好,作者认为需进一步调整儿科推荐。
要点
- ACR TI-RADS评分者间一致性显著优于Kwak-TI-RADS(P<0.001)。
- 两者诊断性能无显著差异,AUROCC分别为0.72和0.74。
- 两种指南对儿童甲状腺结节均提供中等程度恶性风险分层。
核心结论
- Kwak-TI-RADS与ACR TI-RADS对儿童甲状腺结节均提供中等程度恶性风险分层,ACR TI-RADS评分者间一致性更好,但两者诊断性能无显著差异。
研究设计与样本
- 回顾性研究,纳入75例在三级儿科医院接受甲状腺超声的儿童,由3名儿科放射科医师和1名儿科放射学研究员分别按Kwak-TI-RADS和ACR TI-RADS评分;以组织病理学/细胞学或2年超声随访稳定为参考标准。
诊断标准与关键数值
- Kwak-TI-RADS的AUROCC为0.74(95%CI 0.67-0.82),ACR TI-RADS的AUROCC为0.72(95%CI 0.61-0.82),两者ROC曲线无显著差异。
局限性
- 作者结论指出需进一步调整儿科患者的推荐。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The Kwak Thyroid Imaging Reporting and Data System (Kwak-TI-RADS) guideline (2011) and American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) guideline (2017) were developed as ultrasound (US) risk stratification tools for detecting thyroid malignancy in adults.
OBJECTIVE: The purpose of this study was to investigate the inter-rater reliability and diagnostic performance of the ACR TI-RADS guideline in the pediatric population and compare it to the Kwak guideline.
MATERIALS AND METHODS: This retrospective study comprised 75 children who underwent thyroid US at a tertiary-level pediatric hospital. Three pediatric radiologists and one pediatric radiology fellow graded the US findings using the Kwak-TI-RADS and ACR TI-RADS guidelines. We assessed reliability of radiologists' ratings using percentage inter-rater agreement, and intra-class correlation coefficients (ICC2,1). We assessed area-under-the-receiver-operating-characteristic curve (AUROCC) to compare the discriminative diagnostic ability of the Kwak-TI-RADS and ACR TI-RADS scoring systems against histopathology/cytology, or stability on US over a 2-year follow-up period for cases without tissue diagnosis.
RESULTS: The inter-rater agreement was significantly better for the ACR TI-RADS level compared to the Kwak-TI-RADS level (P<0.001) using the percentage pairwise agreement. The ROC curves for assessing the diagnostic performance of the two methods showed no significant difference between the methods. The AUROCCs for the Kwak-TI-RADS and ACR TI-RADS levels were 0.74 (95% confidence interval [CI] 0.67-0.82) and 0.72 (95% CI 0.61-0.82), respectively.
CONCLUSION: Both the Kwak-TI-RADS and ACR TI-RADS guidelines provide moderate malignancy risk stratification for thyroid nodules in the pediatric population, with better inter-rater agreement for the ACR TI-RADS guideline. Further work to adjust the recommendations for pediatric patients is necessary.