文献速递腹部介入US

三维超声造影融合成像:评估肝细胞癌射频消融适形边缘的新技术

3-D Contrast-Enhanced Ultrasound Fusion Imaging: A New Technique to Evaluate the Ablative Margin of Radiofrequency Ablation for Hepatocellular Carcinoma.
PubMed 文献 · Ultrasound Med Biol · 2019-05-17

本研究纳入84例肝细胞癌患者,在射频消融前后行三维超声造影融合成像,由两名放射科医生独立评估消融边缘。自动配准成功率57.1%(48/84),耗时4-12秒;交互配准成功率91.7%(77/84),两名医生耗时分别为4.2±1.8分钟和4.8±2.1分钟。观察者间一致性极好(kappa=0.914),消融边缘<5 mm者的局部肿瘤进展率显著高于≥5 mm者(p=0.024)。

要点

  • 三维超声造影融合成像可在射频消融后即时定量评估消融边缘,观察者间一致性极好(kappa=0.914)。
  • 消融边缘<5 mm者的局部肿瘤进展率显著高于消融边缘≥5 mm者(p=0.024)。
  • 自动配准成功率57.1%(48/84),交互配准成功率91.7%(77/84)。

核心结论

  • 采用三维超声造影融合成像在肝细胞癌射频消融后即时定量评估消融边缘是可行的。

研究设计与样本

  • 单中心研究,纳入84例肝细胞癌患者,采集射频消融前及消融后三维超声造影图像进行融合,由两名放射科医生独立评估消融边缘;评估自动配准与交互配准的成功率、耗时及影响因素,观察者间对消融边缘分类的一致性,以及局部肿瘤进展率。

诊断标准与关键数值

  • 消融边缘<5 mm者的局部肿瘤进展率显著高于消融边缘≥5 mm者(p=0.024);观察者间对消融边缘分类的一致性kappa=0.914。

临床应用与阅片要点

  • 射频消融后可采用三维超声造影融合成像即时定量评估消融边缘,消融边缘<5 mm与局部肿瘤进展风险升高相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

To investigate the feasibility of assessing the ablative margin (AM) of radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC) with 3-D contrast-enhanced ultrasound fusion imaging (3-DCEUS-FI), pre- and post-RFA 3-DCEUS images of 84 patients with HCC were fused for two radiologists to independently assess the AMs. The success rate, duration and influencing factors for registration; inter-observer agreement for AM classification; and local tumor progression (LTP) rate were evaluated. The success rate of the automatic registration (AR), which was completed within 4-12 s, was 57.1% (48/84). The duration and success rate of the interactive registration (IR) were 4.2 ± 1.8 min and 91.7% (77/84) for radiologist A and 4.8 ± 2.1 min and 91.7% (77/84) for radiologist B, respectively. The multivariate analysis demonstrated that the pre-RFA image quality, number of vessels (≥3 mm) and presence of acoustic shadow were independent factors for AR (p < 0.05), while the number of vessels was an independent factor for IR (p = 0.001). The agreement between observers was excellent (kappa = 0.914). LTP rate was significantly higher for AMs <5 mm than for AMs ≥5 mm (p = 0.024). Quantitatively evaluating the AM immediately after RFA for HCC with 3-DCEUS-FI was feasible.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Zhang X, Huang G, Ye J, et al. 3-D Contrast-Enhanced Ultrasound Fusion Imaging: A New Technique to Evaluate the Ablative Margin of Radiofrequency Ablation for Hepatocellular Carcinoma. Ultrasound Med Biol. 2019. PMID: 31109841. doi:10.1016/j.ultrasmedbio.2019.03.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。