小口径隧道式中心静脉导管感染

Infection of Small-Bore Tunneled Central Venous Catheters.
PubMed 文献 · AJR Am J Roentgenol · 2019-04-30

回顾性分析2012至2015年介入放射科置入的182例6-French隧道式中心静脉导管,32例(17.6%)因感染拔除;感染导管拔除时间(95.9天)长于未感染导管(39天,p<0.001),多因素分析显示拔除时间(OR 0.992)和隧道式中心静脉导管史(OR 0.306)与因感染拔除相关。

要点

  • 182例小口径隧道式中心静脉导管中32例(17.6%)因感染拔除。
  • 感染导管平均拔除时间95.9天,长于未感染导管的39天(p<0.001)。
  • 多因素分析仅拔除时间(OR 0.992)和隧道式中心静脉导管史(OR 0.306)与感染拔除相关。

核心结论

  • 导管拔除时间和隧道式中心静脉导管史与因感染拔除隧道式中心静脉导管的增加风险相关。

研究设计与样本

  • 回顾性研究,纳入2012至2015年介入放射科置入的全部6-French隧道式中心静脉导管,仅纳入有明确拔除原因记录的患者,排除经股静脉、经肝和经腰置入者,共182例(女105例[57.7%],男77例[42.3%],平均年龄49.7±16岁),采用t检验、Fisher精确检验和logistic回归分析。

诊断标准与关键数值

  • 32例导管(17.6%)因感染拔除。
  • 未感染导管平均拔除时间39天(SD 57.3),感染导管平均拔除时间95.9天(SD 113.4),p<0.001。
  • 以静脉注射抗生素为置管指征时,因感染拔除的隧道式中心静脉导管数量差异有统计学意义(p=0.04)。
  • 多因素分析:拔除时间p=0.002,OR 0.992(95%CI 0.986-0.998);隧道式中心静脉导管史p=0.01,OR 0.306(95%CI 0.121-0.772)。

临床应用与阅片要点

  • 原文结论指出拔除时间和隧道式中心静脉导管史与因感染拔除隧道式中心静脉导管的增加风险相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study is to evaluate the association of common clinical variables with small-bore tunneled central venous catheter (CVC) infection. MATERIALS AND METHODS. Retrospective data were collected from all small-bore (6-French) tunneled CVCs placed by the interventional radiology service between 2012 and 2015. Only patients who had a documented reason for tunneled CVC removal were included in the analysis to capture all events. Transfemoral, transhepatic, and translumbar placements were excluded to reduce cohort heterogeneity. Multiple clinical variables were collected from a review of the medical record. The t test and Fisher exact test were used for two-group comparisons for continuous variables and categoric variables, respectively. Logistic regression analyses were further used to identify variables that were associated with catheter infection. RESULTS. One hundred eighty-two patients (105 women [57.7%] and 77 men [42.3%]) with a mean (± SD) age of 49.7 ± 16 years were included. Thirty-two catheters (17.6%) were removed because of infection. Noninfected lines were removed at a mean of 39 (SD, 57.3) days, whereas infected lines were removed at a mean of 95.9 (SD, 113.4) days after placement (p < 0.001). There was a statistically significant difference in the number of tunneled CVCs removed for infection when the indication for tunneled CVC placement was the administration of IV antibiotics (p = 0.04). By multivariate analysis, only time to removal (p = 0.002; odds ratio, 0.992; 95% CI, 0.986-0.998) and a history of tunneled CVC (p = 0.01; odds ratio, 0.306; 95% CI, 0.121-0.772) were associated with catheter removal for infection. CONCLUSION. Time to catheter removal and history of tunneled CVC were associated with an increased risk of tunneled CVC removal because of infection.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Black JR, Coker MA, Li Y, et al. Infection of Small-Bore Tunneled Central Venous Catheters. AJR Am J Roentgenol. 2019. PMID: 31039030. doi:10.2214/AJR.18.21072

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。