儿童颈部CT的辐射剂量与图像质量

Radiation Dose and Image Quality in Pediatric Neck CT.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-05-23

回顾性分析179例0-16岁儿童颈部CT,比较低剂量方案实施前后(基线75例、低剂量104例)的CT剂量指数容积、剂量长度乘积、图像质量评分与信噪比;低剂量方案在10-16岁组图像质量评分降低、在0-4岁和10-16岁组信噪比降低,但两组合计分别有97%(73/75)和96%(100/104)的检查图像质量足以做出临床诊断。

要点

  • 低剂量方案下10-16岁组图像质量评分低于基线组,0-4岁和5-9岁组未见降低。
  • 低剂量方案下0-4岁和10-16岁组信噪比低于基线组,5-9岁组未见降低。
  • 基线组97%(73/75)、低剂量组96%(100/104)的检查图像质量足以做出临床诊断。

核心结论

  • 低剂量CT方案采集的图像被认为足以做出临床诊断;初步结果提示,使用迭代重建算法可能有机会在不影响诊断图像质量的前提下进一步降低辐射剂量。

研究设计与样本

  • 回顾性研究,共179例0-16岁儿童颈部CT,低剂量方案实施前75例、实施后104例,按0-4岁、5-9岁、10-16岁分为3个年龄组。

关键影像表现/征象

  • 信噪比通过真声带水平的轴位图像计算。
  • 3名神经放射学医师采用5点评分系统评估同一CT扫描的图像质量。

诊断标准与关键数值

  • 图像质量采用5点评分系统评估,由3名神经放射学医师完成。
  • 基线组97%(73/75)的检查图像质量足以做出临床诊断,低剂量组为96%(100/104)。

局限性

  • 原文为回顾性研究。
  • 作者称其结果为初步结果,提示使用迭代重建算法可能有机会在不影响诊断图像质量的前提下进一步降低辐射剂量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Optimization of pediatric neck CT protocols is of critical importance in order to maintain good diagnostic image quality while reducing the radiation burden. Our aim was to evaluate the image quality of pediatric neck CT studies before and after the implementation of a low radiation dose protocol.

MATERIALS AND METHODS: We retrospectively reviewed 179 pediatric neck CT studies, 75 before and 104 after the implementation of low-dose protocols, performed in children 0-16 years of age. The 2 cohorts were divided into 3 age groups, 0-4, 5-9, and 10-16 years. The signal-to-noise ratio was calculated using the axial image through the true vocal folds. Three neuroradiologists assessed the image quality of the same CT scan using a 5-point scoring system. We compared the CT dose index volume, dose-length product, image-quality ratings, and SNR of studies conducted at baseline and with low-dose protocols.

RESULTS: Image-quality ratings were lower in the low-dose than in the baseline cohort in children 10-16 years of age, but not in children 0-4 and 5-9 years of age. The SNR was lower in the low-dose cohort than in the baseline cohort in children 0-4 and 10-16 years of age, but not in children 5-9 years of age. Despite the decrease in image-quality scores in older children, 97% of the studies (73/75) in the baseline cohort and 96% of studies (100/104) in the low-dose cohort were considered of sufficient image quality.

CONCLUSIONS: Images acquired with the low-dose CT protocols were deemed to be of sufficient quality for making a clinical diagnosis. Our initial results suggest that there may be an opportunity for further radiation dose reduction without compromising diagnostic image quality using iterative reconstruction algorithms.