PubMed 文献 · Eur J Radiol · 2019-03-22

纳入70例膝关节韧带重建术后患者共92条完整肌腱移植物,评估双能CT胶原物质分解技术显示移植物的可靠性。多数重建韧带总可视化评分≥5分(满分6分),ACL组为4.3±0.7分且评分0出现频率达15.7%;自体与异体移植物评分无显著差异,观察者间一致性0.71–0.93。

要点

  • 双能CT胶原物质分解可定性显示膝关节韧带重建术后肌腱移植物,多数韧带总可视化评分≥5分(满分6分)。
  • ACL移植物总可视化评分较低(4.3±1.7分),评分0出现频率15.7%,评估时需更加谨慎。
  • 自体与异体移植物可视化评分无显著差异(p>0.05),观察者间一致性0.71–0.93。

核心结论

  • 双能CT胶原物质分解技术可能是定性显示膝关节韧带重建术后肌腱移植物的有用工具,但评估ACL移植物时需要更加谨慎。

研究设计与样本

  • 研究纳入2016年6月至2018年1月间行膝关节双能CT的70例膝关节韧带重建术后患者(平均年龄29.8岁,范围15–57岁;男61例,女9例),评估92条经MRI与临床评估或二次关节镜确认的完整肌腱移植物(自体移植物37条,异体移植物50条)。

关键影像表现/征象

  • 重建韧带按近段、中段、远段分别以三点量表评分:0分为无「双能彩色染色」,1分为部分「双能彩色染色」,2分为完全「双能彩色染色」。
  • 除ACL外,各韧带总可视化评分均值≥5分(满分6分):PCL 5.0±0.8、MCL 5.4±0.7、LCL 5.5±0.5、PLC 5.4±1.0、ALL 5.3±0.6、MPFL 5.8±0.5。
  • ACL组总可视化评分均值为4.3±1.7分。
  • ACL组评分0的出现频率为15.7%,其余各组低于5%或为0%。
  • 自体移植物与异体移植物总可视化评分均值无显著差异(p>0.05)。

诊断标准与关键数值

  • 以三点量表评估每条重建韧带的近段、中段、远段双能彩色染色:0分为无染色,1分为部分染色,2分为完全染色,总分为6分。
  • ACL组总可视化评分均值4.3±1.7分,评分0出现频率15.7%。
  • PCL组总可视化评分均值5.0±0.8分。
  • MCL组总可视化评分均值5.4±0.7分。
  • LCL组总可视化评分均值5.5±0.5分;PLC组5.4±1.0分;ALL组5.3±0.6分;MPFL组5.8±0.5分。

临床应用与阅片要点

  • 双能CT胶原物质分解彩色映射图可用于定性显示膝关节韧带重建术后的肌腱移植物。
  • 评估ACL移植物时需更加谨慎,因其总可视化评分较低且评分0出现频率达15.7%。
  • 自体移植物与异体移植物的可视化评分无显著差异(p>0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this article is to assess whether dual-energy CT (DECT) collagen material decomposition technique could reliably depict graft integrity in patients with knee ligament reconstruction.

METHODS: Seventy patients (mean age, 29.8 years; age range, 15-57 years; 61 men, 9 women) who underwent knee DECT, from June 2016 to January 2018, after knee ligament reconstruction were included in our study. A total of 92 intact tendon grafts (autograft, n = 37; allograft, n = 50), confirmed by MRI and clinical assessment or second-look arthroscopy of the operated knee, were evaluated. The type and number of reconstructed ligaments were as follows: anterior cruciate ligament (ACL) (n = 30), posterior cruciate ligament (PCL) (n = 20), medial collateral ligament (MCL) (n = 12), lateral collateral ligament (LCL) (n = 10), posterolateral ligamentous complex (PLC) (n = 7), anterolateral ligament (ALL) (n = 6), and medial patellofemoral ligament (MPFL) (n = 7). All DECT tendon-specific color mapping images were analyzed by two radiologists independently. Each reconstructed ligament was divided into proximal, middle, and distal portion and rated separately using a three-point scale (0 = absent 'dual-energy color staining'; 1 = partial 'dual-energy color staining'; 2 = full 'dual-energy color staining').

RESULTS: The mean of total visualization scores of reconstructed ligaments were 5 or more out of 6 points (PCL: 5.0 ± 0.8; MCL: 5.4 ± 0.7; LCL: 5.5 ± 0.5; PLC: 5.4 ± 1.0; ALL: 5.3 ± 0.6; MPFL: 5.8 ± 0.5), except for ACL (4.3 ± 1.7). No significant difference was observed in the mean of total visualization scores between the autografts and allografts (p > 0.05). The frequency of the score 0 was greater than 10% for the ACL group (15.7%), while less than 5% or 0% for the other groups. Overall, substantial to almost perfect interobserver agreement (range 0.71-0.93) was found for all types of ligaments.

CONCLUSION: DECT collagen material decomposition technique could be a valuable tool to qualitatively display tendon grafts in the patients with knee ligament reconstruction, but more caution would be needed to assess ACL graft.

来源:Eur J Radiol,查看原文。版权归原作者所有。