文献速递骨肌MR

磁共振关节造影评估非创伤性多向肩关节不稳患者的下关节囊松弛

Evaluation of Inferior Capsular Laxity in Patients with Atraumatic Multidirectional Shoulder Instability with Magnetic Resonance Arthrography.
PubMed 文献 · Korean J Radiol · 2019-01-01

回顾性比较65例非创伤性多向肩关节不稳(MDI)患者与65例无肩关节不稳对照者的磁共振关节造影(MRA)图像,采用新提出的盂肱关节囊(GC)比率法测量下关节囊冗余。MDI组横截面积(CSA)和GC比率均显著高于对照组(均P<0.001),GC比率>1.42诊断MDI的敏感度为92.3%、特异度为89.2%,作者认为GC比率可简便、准确地筛查肩关节MDI。

要点

  • GC比率>1.42提示肩关节MDI,敏感度92.3%、特异度89.2%。
  • MDI患者斜冠状位GC比率和横截面积均显著高于无 instability 对照。
  • 矢状位和轴位囊-头比率在两组间无显著差异,阅片时不必依赖。

核心结论

  • GC比率测量简便,可准确筛查肩关节MDI;GC比率>1.42对MDI最具提示意义,敏感度92.3%、特异度89.2%,优于横截面积。

研究设计与样本

  • 回顾性研究,纳入8年间治疗的肩关节MDI患者65例(男57例、女8例;平均年龄24.5岁,范围18-42岁)和无肩关节不稳对照组65例(男57例、女8例;平均年龄27.4岁,范围18-45岁),由两名骨科外科医生评审在MRA斜矢状位、轴位和斜冠状位图像上测量。

诊断标准与关键数值

  • 在斜冠状位MRA图像上测量盂肱关节囊(GC)比率,以GC比率>1.42为最提示肩关节MDI的阈值,敏感度92.3%、特异度89.2%;MDI组与对照组的横截面积和GC比率均差异显著(均P<0.001),而斜矢状位囊-头比率(P=0.317)和轴位囊-头比率(P=0.053)无显著差异。

临床应用与阅片要点

  • 作者认为GC比率可简便测量并用于准确筛查肩关节MDI;GC比率>1.42对MDI最具提示意义,诊断敏感度92.3%、特异度89.2%。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare inferior capsular redundancy by using magnetic resonance arthrography (MRA) images in patients with multidirectional instability (MDI) of the shoulder and control subjects without instability and thereby develop a screening method to identify the presence of shoulder MDI.

MATERIALS AND METHODS: The MRA images of patients with MDI of the shoulder (n = 65, 57 men, 8 women; mean age, 24.5 years; age range, 18-42 years) treated over an eight-year period were retrospectively reviewed; a control group (n = 65, 57 men, 8 women; mean age, 27.4 years; age range, 18-45 years) without instability was also selected. The inferior capsular redundancy was measured using a new method we named the glenocapsular (GC) ratio method. MRA images of both groups were randomly mixed together, and two orthopedic surgeon reviewers measured the cross-sectional areas (CSAs) and sagittal capsule-head ratios on oblique sagittal images, as well as the axial capsule-head ratios on axial images and GC ratios on oblique coronal images.

RESULTS: The CSAs and GC ratios were significantly higher in patients than in controls (both, p < 0.001); however, the sagittal capsule-head ratios and axial capsule-head ratios were not significantly different (p = 0.317, p = 0.053, respectively). In addition, GC ratios determined the presence of MDI more sensitively and specifically than did CSAs. A GC ratio of > 1.42 was found to be most suggestive of MDI of the shoulder, owing to its high sensitivity (92.3%) and specificity (89.2%).

CONCLUSION: GC ratio can be easily measured and used to accurately screen for MDI of the shoulder.

来源:Korean J Radiol,查看原文。版权归原作者所有。