文献速递骨肌US

手部屈肌腱撕裂断端超声定位:一项尸体研究

Ultrasound localization of lacerated flexor tendon ends in the hand: a cadaveric study.
PubMed 文献 · Skeletal Radiol · 2019-05-21

研究由一位肌骨放射科医生在6只尸体手的96个Ⅱ区屈肌腱断端上用超声定位断端相对撕裂处的距离,并与解剖结果对照。全层撕裂识别正确率99.0%,断端位置在10 mm内准确率92.7%、5 mm内69.8%,平均低估回缩3.5 mm。作者认为有经验的放射科医生用超声识别完全撕裂并在1 cm内定位断端准确率较高。

要点

  • 全层屈肌腱撕裂超声识别正确率99.0%(5/96条肌腱)。
  • 断端位置在10 mm内准确率92.7%(89/96条肌腱),5 mm内69.8%(67/96条肌腱)。
  • 超声预测回缩距离平均低估3.5 mm,误差以低估(61.5%)多于高估(29.2%)。

核心结论

  • 新鲜尸体研究显示,由有经验的放射科医生操作,超声识别完全性肌腱撕裂的准确率为99.0%,在1 cm内定位肌腱断端的准确率为92.7%。

研究设计与样本

  • 新鲜尸体研究,使用6只尸体手的96个Ⅱ区屈肌腱断端,由一位肌骨放射科医生行超声定位,记录每个断端相对撕裂处的距离,随后解剖并比较肌腱位置与超声位置。

关键影像表现/征象

  • 超声可识别Ⅱ区屈肌腱浅、深肌腱的全层撕裂。
  • 超声预测的肌腱回缩距离与解剖确认的回缩距离平均相差3.5 mm,表现为低估。

诊断标准与关键数值

  • 全层撕裂识别正确率99.0%(5/96条肌腱)。
  • 断端位置在10 mm内准确率92.7%(89/96条肌腱)。
  • 断端位置在5 mm内准确率69.8%(67/96条肌腱)。
  • 误差低估回缩61.5%(59/96条肌腱),高估回缩29.2%(28/96条肌腱)。

临床应用与阅片要点

  • 有经验的放射科医生可用超声识别完全性肌腱撕裂并在1 cm内定位断端。
  • 超声预测断端回缩距离倾向于低估,平均低估3.5 mm。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Flexor tendon repair currently requires extensive exposure to locate and repair tendons. Ultrasound (US) has been used to identify lacerated tendon ends with little information on accuracy. This study was designed to measure the accuracy of US to localize tendon ends in zone II flexor tendon lacerations in a cadaveric model.

MATERIALS AND METHODS: US was used to locate tendon ends in zone II lacerations of fingers of six cadaveric hands (96 tendon ends) by a musculoskeletal radiologist. The distance of each tendon end relative to the laceration was recorded. Specimens were dissected and tendon position was compared to US position.

RESULTS: The radiologist correctly identified full-thickness lacerations of both superficial and deep tendons 99.0% (n = 05/96 tendons) of the time. The average difference between mean US predicted retraction and anatomic confirmed retraction for all digits all tendons was 3.5 mm of underestimation. US correctly identified the position of all tendon stumps to within 10 mm 92.7% (n = 89/96 tendons) of the time and 69.8% (n = 67/96 tendons) of the time to within 5 mm. Error tended to underestimate (61.5%; 59/96 tendons) rather than overestimate retraction (29.2%; 28/96 tendons).

CONCLUSIONS: This fresh cadaveric study has demonstrated that with an experienced radiologist, there was 99.0% accuracy identifying a completed tendon tear and locating the tendon ends with US to within 1 cm was 92.7% accurate.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Alvarez DA, Ballard DH, Carroll T, et al. Ultrasound localization of lacerated flexor tendon ends in the hand: a cadaveric study. Skeletal Radiol. 2019. PMID: 31114969. doi:10.1007/s00256-019-03237-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。