文献速递甲状腺与浅表头颈US

预测甲状腺结节恶性时,胸锁乳突肌与甲状腺实质哪个是应变弹性成像的最佳参考组织

Which Is the Best Reference Tissue for Strain Elastography in Predicting Malignancy in Thyroid Nodules, the Sternocleidomastoid Muscle or the Thyroid Parenchyma?
PubMed 文献 · J Ultrasound Med · 2019-04-29

本研究前瞻性纳入83例患者共101个甲状腺结节,比较以胸锁乳突肌(SR1)和周围正常甲状腺组织(SR2)为参考的两种应变比。良恶性结节的SR1均值均显著高于SR2;SR1与SR2均能显著鉴别良恶性,但SR1曲线下面积优于SR2(差异P=0.046)。结论认为SR1与SR2均为有效辅助诊断工具,以胸锁乳突肌为参考可能更有价值。

要点

  • 以胸锁乳突肌为参考的应变比SR1诊断准确性优于以甲状腺组织为参考的SR2(P=0.046)。
  • 良性与恶性结节中SR1均值均显著高于SR2均值(P=0.001;P<0.001)。
  • SR1与SR2均能显著区分甲状腺结节良恶性(两者P<0.001)。

核心结论

  • SR1与SR2均为识别恶性甲状腺结节的有效辅助诊断工具;使用胸锁乳突肌而非甲状腺组织作为参考点可能是测量应变比的更有价值方式。

研究设计与样本

  • 前瞻性研究,纳入83例患者共101个结节;计算每个结节的SR1(胸锁乳突肌应变与甲状腺结节应变之比)和SR2(周围正常甲状腺组织应变与甲状腺结节应变之比),并比较两者均值。

诊断标准与关键数值

  • 101个结节中良性81个(80.2%),恶性20个(19.8%)。
  • 良性结节中SR1均值显著高于SR2均值(P=0.001),恶性结节中SR1均值亦显著高于SR2均值(P<0.001)。
  • SR1与SR2鉴别良恶性的曲线下面积差异有统计学意义(P=0.046),SR1诊断准确性优于SR2。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to compare 2 types of strain ratios (SRs) in thyroid nodules. Two reference points were used: the sternocleidomastoid (SCM) muscle and the thyroid parenchyma.

METHODS: A total of 101 nodules in 83 patients were prospectively enrolled in the study. For the semiquantitative analysis, 2 types of SRs were used: SR1, the ratio of the SCM muscle strain to the thyroid nodule strain; and SR2, the ratio of the surrounding normal thyroid tissue strain to the thyroid nodule strain. For each nodule, the SR1 and SR2 elastographic values were calculated, and their averages were compared.

RESULTS: Eighty-one (80.2%) of 101 thyroid nodules were benign, and 20 (19.8%) were malignant. In both benign and malignant histopathologic types, the SR1 averages were significantly higher than the SR2 averages (P = .001; P < .001, respectively). Both the SR1 and SR2 values were found to be significantly successful in differentiating benign from malignant histopathologic types (P < .001 for both). The areas under the curve were then compared for the methods, and the difference was found to be statistically significant (P = .046). The diagnostic accuracy of the SR1 was superior to that of the SR2.

CONCLUSIONS: The SR1 and SR2 are effective adjunctive diagnostic tools for identifying malignant thyroid nodules. Using the SCM muscle as a reference point instead of thyroid tissue may be a more valuable way to measure SRs.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Görgülü FF. Which Is the Best Reference Tissue for Strain Elastography in Predicting Malignancy in Thyroid Nodules, the Sternocleidomastoid Muscle or the Thyroid Parenchyma? J Ultrasound Med. 2019. PMID: 31037753. doi:10.1002/jum.15013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。