文献速递乳腺US

剪切波弹性成像在鉴别乳腺良恶性微钙化中的价值

Value of Shear Wave Elastography for the Differentiation of Benign and Malignant Microcalcifications of the Breast.
PubMed 文献 · AJR Am J Roentgenol · 2019-04-30

研究纳入74例乳腺X线摄影发现可疑微钙化的患者,对超声可识别的29组微钙化行剪切波弹性成像(SWE)评估,并以超声引导下10G真空辅助活检病理为参考。恶性钙化硬度显著高于良性(p=0.0004),SWE诊断恶性的AUC为0.89、敏感度69%、特异度100%。作者认为SWE有潜力以高特异度鉴别超声可识别的乳腺良恶性微钙化。

要点

  • SWE诊断乳腺微钙化恶性的特异度为100%、敏感度69%,AUC为0.89。
  • SWE检测浸润性成分的AUC为0.93、敏感度75%、特异度100%。
  • 恶性微钙化硬度显著高于良性微钙化(p=0.0004)。

核心结论

  • SWE对超声可识别的乳腺微钙化有潜力以高特异度鉴别良恶性。

研究设计与样本

  • 2016年2月9日至6月23日纳入74例乳腺X线摄影发现可疑微钙化的患者,对超声识别出的微钙化行SWE评估,随后在超声引导下用10G真空辅助针活检,以病理为参考标准;采用Mann-Whitney U检验比较良恶性及纯导管原位癌与含浸润成分病变的弹性和定量结果,并构建ROC曲线。

诊断标准与关键数值

  • SWE诊断恶性的AUC 0.89、敏感度69%、特异度100%、阴性预测值80%、阳性预测值100%、准确率86%;检测浸润性成分的AUC 0.93、敏感度75%、特异度100%、阴性预测值75%、阳性预测值100%、准确率85%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The objective of our study was to evaluate whether shear wave elastography (SWE) can differentiate benign from malignant microcalcifications of the breast when detected on ultrasound (US). SUBJECTS AND METHODS. Between February 9, and June 23, 2016, 74 patients with mammographically detected suspicious microcalcifications underwent breast US. When microcalcifications were identified on US, stiffness was assessed using SWE. Biopsy was subsequently performed under US guidance using a 10-gauge vacuum-assisted needle. Qualitative and quantitative elastography results were compared between benign and malignant calcifications as well as between pure ductal carcinoma in situ and lesions with invasive components using the Mann-Whitney U test. ROC curves were created to assess the performance of SWE in detecting malignancy and invasive components. RESULTS. Twenty-nine groups of microcalcifications in 29 patients were identified on US. At pathology, 16 groups were benign and 13 were malignant. Stiffness of malignant calcifications was significantly higher than that of the benign ones (p = 0.0004). The AUC, sensitivity, specificity, negative predictive value, positive predictive value, and accuracy of SWE for the diagnosis of malignancy were 0.89, 69%, 100%, 80%, 100%, and 86%, respectively, and for detection of an invasive component were 0.93, 75%, 100%, 75%, 100%, and 85%. CONCLUSION. SWE has the potential to differentiate benign from malignant micro-calcifications of the breast when detected on US with high specificity.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Chamming's F, Mesurolle B, Antonescu R, et al. Value of Shear Wave Elastography for the Differentiation of Benign and Malignant Microcalcifications of the Breast. AJR Am J Roentgenol. 2019. PMID: 31039014. doi:10.2214/AJR.18.20899

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。