直立式数字乳腺断层摄影引导真空辅助空心针活检后活检夹标记的即刻迁移
这项回顾性研究评估了直立式数字断层摄影引导真空辅助空心针活检后即刻活检夹迁移率及相关因素,共197次活检,迁移率38%(定义为距活检病灶>0.5 cm),逻辑回归显示乳腺密度降低与即刻迁移更可能相关(BI-RADS乳腺密度每增加一级的估计OR为0.60,95%CI 0.40–0.91,P=0.018)。
要点
- 活检夹即刻迁移率38%,定义为距活检病灶>0.5 cm。
- 乳腺密度降低与即刻活检夹迁移更可能相关(OR 0.60,95%CI 0.40–0.91,P=0.018)。
- 放射科医生应知悉即刻活检夹迁移,正确夹位置可指导术前定位并监测活检部位变化。
核心结论
- 活检后即刻活检夹迁移在乳腺密度降低时更可能发生。
研究设计与样本
- 回顾性研究,2014年11月1日至2016年9月30日单机构197次活检(188例患者),使用直立式数字断层摄影引导真空辅助空心针活检装置,以活检后乳腺X线摄影评估活检夹相对于目标病灶的即刻位置。
关键影像表现/征象
- 活检后乳腺X线摄影用于评估活检夹相对于目标病灶的即刻位置。
- 活检病灶类型包括钙化(n=159)、结构扭曲(n=29)、肿块(n=5)及不对称(n=4)。
- 即刻活检夹迁移率38%,定义为距活检病灶>0.5 cm。
诊断标准与关键数值
- 即刻活检夹迁移定义为距活检病灶>0.5 cm。
- BI-RADS乳腺密度每增加一级的估计OR为0.60(95%CI 0.40–0.91),P=0.018,迁移在乳腺密度降低时更可能发生。
临床应用与阅片要点
- 放射科医生应知悉即刻活检夹迁移,正确夹位置可指导术前定位并允许在 future mammograms 上监测活检部位变化。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The goal of this retrospective study was to evaluate the rate of immediate post-biopsy clip migration on an upright digital tomosynthesis-guided vacuum-assisted core biopsy unit and determine if any factors were associated with immediate clip migration.
MATERIALS AND METHODS: We performed a retrospective review of patients who had undergone a biopsy performed at one facility from November 1, 2014 to September 30, 2016. Post-biopsy mammograms were reviewed to assess immediate clip position relative to the targeted lesion. The effects of age, lesion type, breast density, biopsy approach, number of samples, size of the biopsy chamber, and clip type on clip migration were examined using logistic regression analysis.
RESULTS: One hundred ninety-seven biopsies were performed on 188 patients for calcifications (n = 159), architectural distortions (n = 29), masses (n = 5), and asymmetries (n = 4). The clip migration rate was 38% as defined as greater than 0.5 cm from the site of the biopsied lesion. The only independently predictive variable of clip migration was breast density in a numeric covariate in the logistic regression model, as migration was more likely with decreased breast density. The estimated odds ratio for a single level increase in BI-RADS breast density was 0.60 (95% confidence interval: 0.40, 0.91) with p = 0.018.
CONCLUSION: Immediate clip migration following biopsy was more likely with decreased breast density. Radiologists should be aware of immediate clip migration as correct clip location guides preoperative localization and allows the biopsy site to be monitored for changes on future mammograms.
引用
- Teichgraeber DC, Martaindale S, Omofoye TS, et al. Immediate Migration of Biopsy Clip Markers After Upright Digital Breast Tomosynthesis-Guided Vacuum-Assisted Core Biopsy. Acad Radiol. 2019. PMID: 31076332. doi:10.1016/j.acra.2019.03.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。